著者
森内 茂 堤 正博 斎藤 公明
出版者
日本保健物理学会
雑誌
保健物理 : hoken buturi (ISSN:03676110)
巻号頁・発行日
vol.42, no.1, pp.71-83, 2007-03
被引用文献数
4

Gamma ray spectra analyses using unfolding techniques and the dose evaluation are performed widely in the fields of environmental radiation monitoring and the relating environmental research. Various sizes and the shapes of NaI (Tl) scintillation detectors can be used depending on the dose levels. However, available response functions are generally limited to 3"φ×3" cylindrical and 3"φ spherical types and the energy range is roughly up to 3 MeV. In this paper, the response functions of eight types of cylindrical and spherical NaI (Tl) scintillation detectors (1"φ×1", 2"φ×2", 3"φ×3", 4"φ×4", 5"φ×4" cylindrical, and 2"φ, 3"φ, 5"φ spherical) were determined. The energy ranges were extended to 10 MeV in maximum. The some response functions reported in literatures were unfolded using our response matrices for comparison and the relative characteristics were discussed.

言及状況

外部データベース (DOI)

Twitter (2 users, 2 posts, 6 favorites)

めも 各種形状寸法のNaI(Tl)シンチレーション検出器のγ線応答関数の整備と試験 http://t.co/b5dAJpmBif

収集済み URL リスト