We have constructed and tested a shell and tube heat exchanger with a dual speaker thermoacoustic device. We have tested a shell and tube heat exchanger by changing the phase between two speakers at both ends of the device. Five thermocouples are positioned within the regenerator and inlet and outlet water temperature were measured with two other thermocouples. Two pressure sensors are positioned each side of the device along the regenerator. We have measured the regenerator temperature and pressure at both sides of the regenerator with changing the mass flow rate of coolant water. The temperature distribution of regenerator and the acoustic power were gained from measured values.