The partial flow dilution method is one of the typical measurement methods for particulate matter emission from diesel engines. In this method, exhaust gas at a transient flow rate should be transferred to a dilution tunnel at a constant ratio of exhaust gas. The present partial flow dilution method is used under steady-state engine operating conditions in lieu of direct flow rate measurement of exhaust gas. A more practical control of exhaust emission is, however, required world widely; therefore development of an exhaust gas flowmeter is indispensable in the partial flow dilution method for transient engine operating conditions. An ultrasonic exhaust gas flowmeter has been developed and been demonstrated to be capable of measuring the exhaust gas flow rate with sufficient accuracy.