- 著者
-
キム スンヨン
杉本 俊樹
荒木 拓人
- 出版者
- 一般社団法人 日本機械学会
- 雑誌
- マイクロ・ナノ工学シンポジウム
- 巻号頁・発行日
- vol.2014, pp._21am2-A6--_21am2-A6-, 2014
Proton exchange membrane fuel cells (PEMFCs) are useful systems because they operate at lower temperatures than other types of fuel cells. This characteristic causes water management issues. To elucidate effects of water on PEMFC performance, we developed a temperature sensor using micro-electro-mechanical systems (MEMS) techniques. This sensor was placed between the catalyst layer (CL) and the microporous layer (MPL) at the cathode. Slight effects on total cell performance were observed with the insertion of the sensor. This sensor can be applicable to typical PEMFCs without any special equipment such as a transparent separator. In-situ measurement with a temperature sensor showed that the maximum temperature rise at the cathode CL (CCL) was about 9 ℃ at 1.1 A/cm^2. The temperature sensor also showed temperature gradients between the ribs and channels. In addition, we developed a capacitance-type humidity sensor and inserted it in the channel. In-situ measurement with a humidity sensor showed a relative humidity (RH) change in the channel.