- 著者
-
Cem SAHIN
Zafer C. CEHRELI
Muhittin YENIGUL
Bulent DAYANGAC
- 出版者
- 日本歯科理工学会
- 雑誌
- Dental Materials Journal (ISSN:02874547)
- 巻号頁・発行日
- vol.31, no.3, pp.401-408, 2012 (Released:2012-05-28)
- 参考文献数
- 32
- 被引用文献数
-
4
15
To investigate the permeability of deep dentin following immediate sealing with different etch-and-rinse and self-etch adhesives (Single Bond 2, Adper Prompt L-Pop, Clearfil Protect Bond, Clearfil S3 Bond, G-Bond) and a dentin desensitizer (Gluma). Fluid-transport model was used to measure fluid conductance during and after application of adhesives. Polyvinylsiloxane impressions of bonded dentin were taken to monitor fluid transudation from the surface of the adhesives. The area and number of dentinal fluid droplets and/or blisters were calculated using image analysis. None of the adhesives were able to block fluid conductance completely. The fluid conductance values of the adhesives displayed the following statistical ranking (p<0.05): G-Bond≤Clearfil Protect Bond<Smear-layer-covered dentin<S3 Bond≤Single Bond 2≤Adper Prompt L-Pop<Gluma Desensitizer<Acid-etched dentin. Highly significant correlation was observed between the permeability of the tested adhesives and the area fraction of fluid droplets/blisters on the adhesive surfaces (r=0.99, p<0.01).