- 著者
-
Yusuke Torikai
Dai Kuze
Junko Kurosawa
Yasuhiro Oikawa
Yoshio Yamasaki
- 出版者
- 一般社団法人 日本音響学会
- 雑誌
- Acoustical Science and Technology (ISSN:13463969)
- 巻号頁・発行日
- vol.36, no.6, pp.500-506, 2015 (Released:2015-11-01)
- 参考文献数
- 15
- 被引用文献数
-
1
We investigated a new communication-aid system focused on bone-conduction through a tooth, for listening to and recording voices. In this paper, we developed a tooth-conduction microphone (TCM) and evaluate the articulation of tooth-conducted voice (TCV). Because the TCM has the shape of one's dental mold, it is wearable like a mouthpiece. Moreover, it can extract tooth vibration during phonation as TCV. To evaluate articulation of TCV, we adopted monosyllable articulation for subjective assessment and linear predictive coding cepstral distance for objective assessment. The results of articulation show that TCV is not sufficiently clear compared to air-conducted. However, it is confirmed that TCV is robust to environmental noise because the accuracy rate is not decreased when the TCV is recorded under high ambient noise.