著者
Tadashi Omoto Atsushi Aoki Kazuto Maruta Tomoaki Masuda
出版者
The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery
雑誌
Annals of Thoracic and Cardiovascular Surgery (ISSN:13411098)
巻号頁・発行日
pp.oa.22-00135, (Released:2022-11-03)
参考文献数
12

Purpose: We studied the association between operative timing and the feasibility of mitral valve (MV) repair in active infective endocarditis (IE).Methods: Forty-nine active IE patients who underwent MV operation were classified according to operative timing: within 48 hours (Term I: n = 7), between 3 and 14 days (Term II: n = 22), and ≥15 days (Term III: n = 20). Patient profiles, operative outcomes, and feasibility of MV repair were evaluated. Complexity score and severity score were used to define the feasibility of MV repair depending on the extent of infected lesion and technical difficulties.Results: There were no differences in basic profile in the three groups. Rate of major complications was higher in Term I (86%) than II (41%, p = 0.031) and III (25%, p = 0.005). In-hospital mortality was also higher in Term I (43%) than II (9%, p = 0.039) and III (5%, p = 0.015). The three groups did not differ by feasibility of MV repair calculated by the two-score system or by frequency of MV repair (I: 57%, II: 59%, and III: 55%).Conclusions: Morbidity and mortality were high in urgent cases. Feasibility of MV repair is associated with the extent of infected lesion and technical difficulties, and not with operative timing.
著者
Atsushi Aoki Kazuto Maruta Tomoaki Masuda Tadashi Omoto
出版者
The Editorial Committee of Annals of Vascular Diseases
雑誌
Annals of Vascular Diseases (ISSN:1881641X)
巻号頁・発行日
vol.15, no.3, pp.175-185, 2022-09-25 (Released:2022-09-25)
参考文献数
20
被引用文献数
2

Objectives: Appropriateness of device selection, procedure protocol and aortic remodeling effects of entry closure (TEVAR) with stent-graft (SG) for patent false lumen type B aortic dissection (TBAD) were compared between the patients with narrow true lumen (narrow group) and those with aneurysmal dilated false lumen (aneurysmal group).Methods: Twenty-six patients with narrow true lumen (narrow group) and 20 patients with aneurysmal false lumen (aneurysmal group) were included in this study. In narrow group, straight SG was implanted from Zone 3 regardless the distance between the left subclavian artery and entry. In aneurysmal group, straight or taped SG was implanted with proximal landing zone length 20 mm or more. Thoracic aortic anatomy was evaluated by CT and aortic remodeling was defined as true lumen diameter ≥50% of the aortic diameter and occlusion of false lumen. Aorta related death, retrograde type A aortic dissection (RTAD), stentgraft induced new entry (SINE) and aortic maximum diameter enlargement 5 mm or more (aortic expansion) were included in the aortic event.Results: There was no procedure related complication in narrow group and 1 patient died due to aortic rupture in aneurysmal group, Type Ia endoleak by enhanced CT 7 days after TEVAR was detected in one patient in each group. Achievement of aortic remodeling was significantly better in narrow group. Aortic event occurred in only one patient in narrow group, in whom aortic expansion was observed. In aneurysmal group, aortic event occurred 12 patients (60%) and 2 RTAD, 5 SINE, and 8 aorta expansion were observed. Aortic event free rate was significantly better in narrow group.Conclusion: TEVAR procedure for the TBAD patients with narrow true lumen seemed to be appropriate, however, different TEVAR procedure or additional procedures would be required for those with aneurysmal dilated false lumen to obtain favorable outcomes. (This is secondary publication from Jpn J Vasc Surg 2021; 30: 347–357.)