著者
Naoki Ohno Kotaro Yoshida Yu Ueda Yuki Makino Tosiaki Miyati Toshifumi Gabata Satoshi Kobayashi
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0087, (Released:2021-11-02)
参考文献数
26
被引用文献数
5

Purpose: This multi-scanner study aimed to investigate the validity of single breath-hold (BH) diffusion-weighted imaging (DWI) using simultaneous-multislice (SMS) echo-planar imaging in multiple abdominal organs to enable faster acquisition and reliable quantification of apparent diffusion coefficient (ADC).Methods: SNR, geometric distortion (GD), and ADC in a phantom; the ADC in the liver, renal cortex, paraspinal muscle, spleen, and pancreas; and the signal intensity ratio of the portal vein-to-muscle (SIRPV-M) in healthy volunteers were compared between BH- and respiratory-triggered (RT) DWI with b-values of 0 and 800 s/mm2 in two different MRI scanners.Results: The phantom study showed that the SNR of BH-DWI was significantly lower than that of the RT-DWI (P < 0.05 for both scanners), whereas the GD and ADC of BH-DWI did not differ significantly from those of the RT-DWI (P = 0.09–0.60). In the volunteer study, the scan times were 23 seconds for BH-DWI and 184±33 seconds for RT-DWI, respectively. The ADC of the liver in BH-DWI was significantly lower than that in RT-DWI (P < 0.05 for both scanners), whereas there were no significant differences in the ADCs of the renal cortex, paraspinal muscle, spleen, or pancreas between BH-DWI and RT-DWI (P = 0.07–0.86). The SIRPV-M in BH-DWI was significantly smaller than in RT-DWI (P < 0.05 for both scanners).Conclusion: The proposed method enables the acquisition of abdominal diffusion-weighted images in a single BH.
著者
Masako Ohno Naoki Ohno Tosiaki Miyati Hiroko Kawashima Kazuto Kozaka Yukihiro Matsuura Toshifumi Gabata Satoshi Kobayashi
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2020-0103, (Released:2021-02-09)
参考文献数
50
被引用文献数
3

Purpose: To obtain detailed information in breast ductal carcinoma in situ (DCIS) and invasive ductal carcinoma (IDC) using triexponential diffusion analysis.Methods: Diffusion-weighted images (DWI) of the breast were obtained using single-shot diffusion echo-planar imaging with 15 b-values. Mean signal intensities at each b-value were measured in the DCIS and IDC lesions and fitted with the triexponential function based on a two-step approach: slow-restricted diffusion coefficient (Ds) was initially determined using a monoexponential function with b-values > 800 s/mm2. The diffusion coefficient of free water at 37°C was assigned to the fast-free diffusion coefficient (Df). Finally, the perfusion-related diffusion coefficient (Dp) was derived using all the b-values. Furthermore, biexponential analysis was performed to obtain the perfusion-related diffusion coefficient (D*) and the perfusion-independent diffusion coefficient (D). Monoexponential analysis was performed to obtain the apparent diffusion coefficient (ADC). The sensitivity and specificity of the aforementioned diffusion coefficients for distinguishing between DCIS and IDC were evaluated using the pathological results.Results: The Ds, D, and ADC of DCIS were significantly higher than those of IDC (P < 0.01 for all). There was no significant correlation between Dp and Ds, but there was a weak correlation between D* and D. The combination of Dp and Ds showed higher sensitivity and specificity (85.9% and 71.4%, respectively), compared to the combination of D* and D (81.5% and 33.3%, respectively).Conclusion: Triexponential analysis can provide detailed diffusion information for breast tumors that can be used to differentiate between DCIS and IDC.