著者
Takahito Sekiguchi Masao Kato Hideaki Kimoto Toshihiko Amemiya Ko Dezawa Yusuke Imanishi Kunihito Matsumoto Yoshinori Arai
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.65, no.1, pp.40-43, 2023 (Released:2023-01-11)
参考文献数
13
被引用文献数
2

Purpose: The dual imaging plate (DIP) method, which synthesizes intraoral radiographs from a front imaging plate (FIP) and a back imaging plate (BIP), produces adequate image quality and allows the radiation dose to be reduced. However, there are slight errors in superimposition and alignment between the FIP and BIP. The aim of this study was to establish positional correction in the DIP method and evaluate the effect.Methods: Six sets of two imaging plates were used for imaging a mesh plate and a porcine mandible phantom. Subtraction images between FIP and BIP images were synthesized in four steps: correcting horizontal and vertical direction, rotation, enlargement ratio, and enlargement ratio into 12 blocks. Variance of the pixel value on the subtraction images at each step was compared to evaluate the alignment of FIP and BIP images.Results: The variance of the pixel values in the subtraction images was gradually and significantly decreased by each step of image processing (P < 0.01), indicating that the degree of alignment of FIP and BIP images improved during the image processing.Conclusion: The present study revealed that it is possible to synthesize more precise DIP images using an additional four-step image processing technique.
著者
Kenichiro Watanabe Yusuke Imanishi Masao Kato Hideaki Kimoto Takahito Sekiguchi Toshihiko Amemiya Ko Dezawa Kunihito Matsumoto Yoshinori Arai Kazuya Honda
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.21-0454, (Released:2021-12-27)
参考文献数
23
被引用文献数
3

Purpose: This study evaluated the contrast-to-noise ratio (CNR), spatial resolution, and subjective quality of dual imaging plates (DIP) intraoral radiography.Methods: The DIP and conventional single IP (CSIP) methods both used YCR DT-1 imaging plates (Yoshida Co.). The DIP, comprising a front IP (FIP) and back IP (BIP), was constructed. DIP images were synthesized from the FIP and BIP images. An aluminum step phantom was used to measure the CNR. A line pair gauge was used to measure the spatial imaging resolution. A phantom comprising a porcine mandible embedded in acrylic resin was used for subjective evaluation.Results: The CNR of the DIP image was 32% higher than that of the FIP image. The spatial resolution achieved using the FIP, DIP, and CSIP was highly comparable except above 4 line pairs/mm, where that of the CSIP was highest. In subjective evaluation, the noise in the DIP images was significantly lower than in those obtained using the FIP and CSIP.Conclusion: The CNR of the DIP was higher than that of the FIP. The decrease in spatial resolution of the DIP was limited. The subjective image quality of the DIP was higher than that of the FIP.
著者
Ryosuke Koshi Kunihito Matsumoto Yusuke Imanishi Takayuki Kawato Shuichi Sato Shigeki Shimba Yoshinori Arai Kazuya Honda
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.63, no.1, pp.83-86, 2021 (Released:2020-12-23)
参考文献数
33
被引用文献数
6

Purpose: Circadian rhythm is associated with the pathogenesis of systemic disease and bone mineral metabolism. This study aimed to radiographically evaluate morphological characteristics of the interalveolar septum in circadian rhythm deficient animals.Methods: Heads of 10 brain and muscle arnt-like protein-1 (BMAL1)-knockout (KO) mice and 10 wild-type mice sacrificed at 36 weeks were imaged using micro-computed tomography. The mean depth from the cementoenamel junction to the alveolar ridge (virtual bone sounding: VBS) of the interalveolar septum between the first and second molars, and the bone mineral density (BMD) of the interalveolar septum and the mandibular inferior cortex region were calculated. Tooth diameter was also measured.Results: The VBS of the interalveolar septum in the BMAL1-KO mice was significantly deeper than that in wild-type mice. The BMD in the BMAL1-KO mice was significantly lower than in the wild-type mice in both regions. No significant difference was observed in tooth diameter between BMAL1-KO and wild-type mice.Conclusion: These results suggest that low BMD in the interalveolar septum accelerates bone resorption in the interalveolar septum in BMAL1-KO mice.
著者
Yusuke Hayashi Motohiro Ito Yusuke Imanishi Kenichiro Watanabe Kunihito Matsumoto Yoshinori Arai Kazuya Honda
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.19-0307, (Released:2020-06-10)
参考文献数
24

The present study used an aluminum phantom to calculate accurate vertical magnification values around the mental foramen on panoramic radiography (PR) and compared corrected PR (Cor-PR) thickness measurements of the aluminum phantom and mandibular cortical width (MCW) of the human head with cone-beam computed tomography (CBCT) measurements at two fields of view (FOVs). The calculated vertical magnification value for PR around the mental foramen was 1.37. Measurements of the aluminum phantom significantly differed between Cor-PR and CBCT with an FOV of 100 mm and between CBCT with FOVs of 40 and 100 mm; however, MCW measurements did not significantly differ among the three methods. There was a very strong correlation between Cor-PR and CBCT with an FOV of 40 mm and between CBCT with FOVs of 40 mm and 100 mm, and intraobserver and interobserver agreement was good-to-excellent for all methods. These results suggest that Cor-PR and CBCT with small and large FOVs are acceptable for measuring MCW.