著者
Yuta Endo Sanae Takahashi Haruna Shibo Makoto Amanuma Kuninori Kobayashi Shigehide Kuhara
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2023-0029, (Released:2023-09-04)
参考文献数
26

Purpose: Polarity-corrected inversion time preparation (PCTIP), a myocardial T1 mapping technique, is expected to reduce measurement underestimation in the modified Look-Locker inversion recover method. However, measurement precision is reduced, especially for heart rate variability. We devised an analysis using a recurrence formula to overcome this problem and showed that it improved the measurement accuracy, especially at high heart rates. Therefore, this study aimed to determine the effect of this analysis on the accuracy and precision of T1 measurements for irregular heart rate variability.Methods: A PCTIP scan using a 3T MRI scanner was performed in phantom experiment. We generated the simulated R-waves required for electrocardiogram (ECG)-gated acquisition using a signal generator set to 30 combinations. T1 map was generated using the signal train of the PCTIP images by nonlinear curve fitting using conventional and recurrence formulas. Accuracy against reference T1 and precision of heart rate variability were evaluated. To evaluate the fitting accuracy of both analyses, the relative fitting error was calculated.Results: For the longer T1, the fitting error was larger than the short T1, with the conventional analysis showing 10.1±2.0%. The recurrence formula analysis showed a small fitting error less than 1%, which was consistent for all heart rate variability patterns. In the conventional analysis, the accuracy, especially for longer T1, showed a large underestimation of the measurements and poor linearity. However, in the recurrence formula analysis, the accuracy improved at a long T1, and linearity also improved. The Bland–Altman plot showed that it varied greatly depending on the heart rate variability pattern for the longer T1 in the conventional analysis, whereas the recurrence formula analysis suppressed this variation.Conclusion: T1 analysis of PCTIP using the recurrence formula analysis achieved accurate and precise T1 measurements, even for irregular heart rate variability.

言及状況

外部データベース (DOI)

Twitter (1 users, 2 posts, 0 favorites)

MRMS<THCHNICAL NOTE>9月8日早期公開 Novel T1 Analysis Method to Address Reduced Measurement Accuracy Due to Irregular Heart Rate Variability in Myocardial T1 Mapping Using Polarity-corrected Inversion Time Preparation Yuta Endo, et al. https://t.co/ri93KxBkhp
<MAJOR PAPER>9月4日早期公開 Novel T1 Analysis Method to Address Reduced Measurement Accuracy Due to Irregular Heart Rate Variability in Myocardial T1 Mapping Using Polarity-corrected Inversion Time Preparation Yuta Endo, et al. https://t.co/1olQpyp8f3

収集済み URL リスト