著者
和田 俊良 佐藤 龍司 石川 千温 上田 正生
出版者
日本建築学会
雑誌
日本建築学会構造系論文集 (ISSN:13404202)
巻号頁・発行日
vol.61, no.490, pp.179-188, 1996
被引用文献数
9 1

A measurement setup, that is based on the structured light projection method, is developed to obtain a 3-dimensional image of the concrete crack surface. And then authors construct the 2-dimensional analytical method of shape properties from it's 3-dimensional image. Analyzing a measured crack surface by tensioning, some functions are formulated. From the analytical results, the measure sensitivity is about 0.125 millimeter/dot and the sampling interval length is about every millimeters, those were able to show the tendency of the shape properties of the concrete crack surface by tensioning.

言及状況

外部データベース (DOI)

収集済み URL リスト