- 著者
-
井上 裕一
小田切 博之
政木 広幸
- 出版者
- 一般社団法人 日本時計学会
- 雑誌
- 日本時計学会誌 (ISSN:00290416)
- 巻号頁・発行日
- vol.127, pp.3-15, 1988-12-20 (Released:2017-11-09)
A conventional temperature compensation IC system is required to provide an oscillating capacity change-over switch in order that a normal type pace measuring instrument can be used. The new temperature compensation IC system we developed here has realized an "all logical adjustment" without an oscillating capacity change-over switch by introducing a "new method of a pace expression". It has become easier to provide a watch with high accuracy by use of the "all logical adjustment".