著者
山田 忠比古 後田 澄夫 近藤 芳孝
出版者
一般社団法人 電気学会
雑誌
電気学会論文誌A(基礎・材料・共通部門誌) (ISSN:03854205)
巻号頁・発行日
vol.114, no.6, pp.459-466, 1994
被引用文献数
1

Luminosity of wire corona has been observed by the technique of the computed tomography. The light output from wirecorona has been compared with the calculated result. Spatial distributions of space-charge and current density of each type ofcharges carrier in a corona field has been also determined by computing the ionization and attachment process under the Deutschassumption and compared with experimental results.<br>The calculated results along the symmetry axis of the electrodes show very good agreement with measurements.Unfortunately, there is a slight difference between the experimental results and those of the calculation under the Deutschassumption in the distribution of luminosity.