著者
小沼 洋治 林 美智子 林 裕晃 西原 貞光
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.68, no.3, pp.277-282, 2012-03-20 (Released:2012-03-24)
参考文献数
12
被引用文献数
4

We tried to remove contamination of radioisotope (RI) for an X-ray detector (photostimulable phosphor plate; IP) and verified that our procedure suggested by Nishihara et al. was effective for decontamination. The procedure was as follows. First, the IP was kept for approximately twelve hours, and then it was processed [image (A)] as well as a clinical processing mode. Second, using a wet-type chemical wiper, we scavenged the IP to remove the adhered RI on its surface. Then, once again, the IP was kept for approximately fifteen hours and processed [image (B)] in order to check an effect of decontamination. Finally, the two images of (A) and (B) were analyzed using ImageJ, which can be downloaded as a free software, and a percentage of removal was calculated. The procedure was applied to two IPs using the FCR 5501 plus. In the present case, the percentage of removal was approximately 96%. The removed radioisotopes in the chemical wipers were analyzed by Ge detector. Then, 134Cs and 137Cs were found with activities of 2.9 4.3 Bq and 3.5 5.2 Bq, respectively. For three months after that, we cannot see black spots on the IPs owing to the contamination of the RI and there are no defects caused by decontamination using a wet-type chemical wiper.
著者
林 裕晃 西原 貞光 小沼 洋治
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.68, no.5, pp.545-553, 2012-05-20 (Released:2012-05-30)
参考文献数
6
被引用文献数
1

Due to accidents of the nuclear power plants in Fukushima prefecture, a lot of radioisotopes were diffused into the environment. They adhered onto the surface of the X-ray detector (imaging plate; IP) and many black spots were seen on the medical images. The process to count them is important to evaluate the degree of contamination and/or removal. In this study, we aimed to develop a counting method for black spots. Based on the analysis of the medical images having black spots, we summarized that areas affected by the certain black spots were limited to the eight pixels surrounding the most intensive pixel. The newly developed counting method was applied to these nine pixels (3×3 pixels) and selection rules were based on the following two information: 1. differences between the digital value of the most intensive pixel and those of the surrounding eight pixels, and 2. total summation of the digital values in the nine pixels. The estimated image based on our method showed a good concordance with the original image. Therefore, we summarized that our counting method is a powerful tool for estimating numbers of black spots.
著者
西原 貞光 林 裕晃
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.67, no.8, pp.912-915, 2011-08-22 (Released:2011-08-24)
参考文献数
6
被引用文献数
5 1 5

Several hospitals have been observing black spots in medical images, and the radioisotopes (RIs) that cause the spots needs to be removed from the X-ray receptors. Our purpose is to show a flowchart for finding out under which conditions an imaging plate (IP) and other parts (for example, the cassette) are contaminated by RIs and to propose an effective method to remove them. The procedure follows. (1) Is RI activity low? (2) Are the surfaces of other parts contaminated? (3) Is the surface of the IP contaminated? (4) Are the insides of the other parts contaminated? To remove the adhered RIs, we applied a wipe test method using a wet type of chemical wiper. A certain hospital that observed black spots experimented with this method. As a result, the contaminated condition of the X-ray receptor was identified. In addition, we were able to remove the RIs from the IP. Therefore, our procedure is very effective for decontaminating adhered RIs from receptors.
著者
林 裕晃 谷内 翔 神谷 尚武 西原 貞光 富永 正英
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.68, no.3, pp.307-311, 2012-03-20 (Released:2012-03-24)
参考文献数
9
被引用文献数
5 1

In order to obtain an image of scattered X-ray in the diagnosis domain, we have newly developed a pin-hole camera. Because of the necessity of the X-ray shielding, the pin-hole part has a depth corresponding to that of the shielded material. As a result, efficiencies of obliquely incident X-rays are reduced. To decrease the descent of the efficiencies, we developed a large camera using a 10×12 inch size phosphor plate as an X-ray detector. A phantom was irradiated by X-rays with conditions of 500 mAs and 5000 mAs, and images of scattered X-rays were obtained. The former image showed scattered X-rays from the phantom. The latter image showed those from the air of beam axis as well as from the phantom. Moreover, we made a new proposal to obtain an optical image using the fading effect.