著者
根武谷 吾 平賀 琢也 氏平 政伸
出版者
公益社団法人 計測自動制御学会
雑誌
計測自動制御学会論文集 (ISSN:04534654)
巻号頁・発行日
vol.50, no.8, pp.580-587, 2014 (Released:2014-08-15)
参考文献数
21
被引用文献数
1 3

We report the results of a preliminary trial to visualize a cell during freezing process using microscopic electrical impedance tomography (micro-EIT). A printed circuit board was developed for micro-EIT with two measurement chambers, 5mm in diameter and 1.6mm in depth. These chambers were filled with ethanol (2mS/cm) which was then kept at -30°C by placing it on a copper block filled with liquid nitrogen and by using a heater with a programmable controller. A grain of Citrus Sudachi and an egg of Cypselurus Agoo Agoo were placed into the measurement chamber and were recorded data during freezing by using a CCD microscope and micro-EIT. When the sample started freezing, the brightness of the sample became higher and the relative impedance in micro-EIT image also increased. Similar results were obtained in all the four trials respectively. Therefore, these results indicate that EIT is useful to observe freezing process of a cell.