著者
高林 豊 渡邉 信光 岩本 文夫
出版者
日本法科学技術学会
雑誌
日本法科学技術学会誌 (ISSN:18801323)
巻号頁・発行日
vol.12, no.2, pp.197-206, 2007 (Released:2007-10-06)
参考文献数
8

The mechanism of starting a fire from a kerosene fan heater by misusing of gasoline is similar to that from a wich-type kerosene heater. However, a combustion control device and many safety devices of a kerosene fan heater are different from those of a kerosene heater. Therefore, it is necessary to elucidate an outbreak of fire risk by these differences.   In this work, an outbreak of fire risk of a kerosene fan heater by misusing of gasoline was examined through combustion experiments. Then, we confirmed that the mechanism of starting a fire from a kerosene fan heater require fuel leakage as well as a kerosene heater. The difference of the structure of a kerosene fan heater influenced the outbreak of fire mechanism. And a flame sensor that is one of the safety devices was found to detect misusing of gasoline. Moreover, the GC analysis of each component of a burnt-out kerosene fan heater was found to be effective to prove misusing of gasoline.