著者
Mitsuhiro IRIE Takuma MIYOSHI Akira HIRAMOTO Masahiko HIRATA Masamine TAKANOSU Eun-Sil PARK Ken MAEDA
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
vol.84, no.5, pp.675-679, 2022 (Released:2022-05-17)
参考文献数
26
被引用文献数
2

A two-year-old male domestic cat showed lethargy, tonic-clonic convulsion, and mucosal jaundice. Upon admission, blood examination indicated severe neutropenia and thrombocytopenia, and ultrasonography revealed diffuse splenomegaly with a honeycomb appearance and abdominal lymph nodes enlargement in addition to a decrease in cardiac blood flow indicating a shock condition. Cytology of the spleen showed a cell population composed of immature large lymphoid cells with distinct nucleoli, suggesting lymphoma. The cat received symptomatic treatments but died four hours later. Reverse transcriptase polymerase chain reaction assay of the spleen sample indicated the presence of severe fever with thrombocytopenia syndrome (SFTS) virus S gene segment. Clinical features of this case that was diagnose as SFTS were similar to lymphoma. Therefore, pet owners and veterinary workers should be protected against infection of SFTS.
著者
Keitaro MORISHITA Akira HIRAMOTO Tatsuyuki OSUGA Sue Yee LIM Nisa KHOIRUN Noboru SASAKI Kensuke NAKAMURA Hiroshi OHTA Masahiro YAMASAKI Mitsuyoshi TAKIGUCHI
出版者
公益社団法人 日本獣医学会
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.16-0062, (Released:2016-08-18)
被引用文献数
4

Contrast-enhanced ultrasonography (CEUS) of the hepatic vein can assess intrahepatic hemodynamic changes, and has been studied as a noninvasive method to assess the severity of portal hypertension and hepatic fibrosis in humans. However, few reports have described its usefulness in veterinary medicine. The purpose of this study was to characterize CEUS findings of the hepatic vein in normal dogs and assess the repeatability of this method both in a conscious group (n=6) and a sedated group (n=6). Sonazoid® (0.01 ml/kg) was used as a contrast agent and scanning of the hepatic vein was performed for 2 min. Time-intensity curves were generated from regions of interest in the hepatic vein. Four perfusion parameters were measured for quantitative analysis: hepatic vein arrival time (HVAT), time to peak (TTP), time to peak phase (TTPP) and wash-out ratio (WR). CEUS examinations were performed three times in each dog. The median (range) values of HVAT, TTP, TTPP and WR in the conscious group were 13.5 sec (9–22 sec), 12.5 sec (6–24 sec), 8 sec (6–13 sec) and 78.0% (60.7–91.7%), respectively. Median (range) values of HVAT, TTP, TTPP and WR in the sedated group were 12 sec (8–17 sec), 12.5 sec (9–17 sec), 9 sec (7–13 sec) and 84.1% (63.0–94.4%), respectively. The coefficients of variation of these parameters in the conscious and sedated groups were 7.6–29.7% and 11.8%–14.8%, respectively.