著者
Paula Pontevedra Carlos Lopez-Suarez Veronica Rodriguez Celia Tobar Jesus Pelaez Maria J Suarez
出版者
Japan Prosthodontic Society
雑誌
Journal of Prosthodontic Research (ISSN:18831958)
巻号頁・発行日
pp.JPR_D_22_00237, (Released:2023-03-28)
参考文献数
55
被引用文献数
1

Purpose: To evaluate and compare the survival, success rates, and biological and technical complications of three-unit posterior monolithic and veneered zirconia and metal-ceramic (MC) posterior fixed partial dentures (FPDs) fabricated using a digital workflow and computer-aided design and computer-aided manufacturing (CAD/CAM) over a 5-year follow-up.Methods: Ninety patients in need of three-unit posterior FPDs were randomized to receive monolithic zirconia (MZ), veneered zirconia (VZ), and MC restorations (n = 30 each). Teeth preparations were scanned using an intraoral scanner, and restorations were milled and cemented with resin cement. Clinical performance and periodontal parameters were assessed at baseline and yearly up to 5 years after insertion. Data analysis was performed using the Kaplan-Meier method, Friedman test, and Wilcoxon signed-rank test with Bonferroni correction and Mann-Whitney U test.Results: The 5-year survival rates of the MZ, VZ, and MC FPDs were 87%, 97%, and 100%, respectively (P = 0.04). Most complications were biological in nature. Only one MZ FPD fractured 58 months after placement. All the restorations were assessed as satisfactory at each recall. Differences were found in the gingival index score over time in the VZ and MC groups. The margin index remained stable throughout the follow-up period in both zirconia groups.Conclusions: The results of this study suggest that using a digital workflow to fabricate posterior FPDs is an adequate treatment option and that monolithic zirconia could be a viable alternative to metal-ceramic or veneered zirconia. However, further long-term studies are necessary to provide stronger evidence in patients with bruxism.
著者
Carlos LOPEZ-SUAREZ Veronica RODRIGUEZ Jesus PELAEZ Ruben AGUSTIN-PANADERO Maria J. SUAREZ
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2016-391, (Released:2017-08-25)
参考文献数
41
被引用文献数
17

The purpose of this study was to evaluate and to compare the fracture load and the fracture pattern of monolithic and veneered zirconia posterior fixed dental prostheses (FDPs). Twenty standardized steel dies were prepared to receive posterior 3-unit FDPs. Specimens were randomly divided into 2 groups (n=10): (1) Lava Zirconia, and (2) Lava Plus. All FDPs were cemented using glass ionomer cement and subjected to thermal and mechanical cycling at 5–55ºC with a 30-s dwell time for 120,000 masticatory cycles. All specimens were subjected to a three-point bending test until fracture. Data were statistically analyzed using Student’s t test, paired t-test and Weibull statistics (α=0.05). No differences were observed in fracture load between the groups. Veneering ceramic fractured before than framework in veneered zirconia group. The fracture pattern was different. The tested groups demonstrated clinically acceptable fracture load values. Monolithic zirconia solves the chipping problem.