著者
Naoya Kinota Hiroyuki Kameda Bai Xiawei Takaaki Fujii Daisuke Kato Bunya Takahashi Ryo Morita Daisuke Abo Ryusei Majima Hiroshi Ishii Kazuyuki Minowa Kohsuke Kudo
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2023-0023, (Released:2023-05-30)
参考文献数
42
被引用文献数
1

Purpose: To investigate whether deep cervical lymph node (DCLN) ligation alters intracranial cerebrospinal fluid (CSF) tracer dynamics and outflow using a rat model with intrathecal dynamic contrast-enhanced (DCE) MRI.Methods: Six bilateral DCLN-ligated and six sham-operated rats were subjected to DCE MRI with Gd-BTDO3A, and dynamic T1-weighted images were acquired. ROIs were collected from the CSF at the C1 level (CSF_C1), CSF between the olfactory bulbs (CSF_OB), CSF at the pituitary recess (CSF_PitR), and CSF at the pineal recess (CSF_PinR), upper nasal turbinate (UNT), olfactory bulbs, cerebrum, and the jugular region. Time-intensity curves were evaluated, and the maximum slope, peak timing, peak signal ratio, and elimination half-life for the four CSF ROIs and UNT were calculated and compared.Results: Delayed tracer arrival in the rostral CSF space and the nasal cavity with tracer retention in the ventral CSF space were observed in the ligation group. The maximum slopes were smaller in the ligation group at UNT (sham: 0.075 ± 0.0061, ligation: 0.044 ± 0.0086/min, P = 0.011). A significant difference was not detected in peak timings. The peak signal ratio values were lower in the ligation group at UNT (sham: 2.12 ± 0.19, ligation: 1.72 ± 0.11, P = 0.011). The elimination half-life was delayed in the ligation group at CSF_C1 (sham: 30.5 ± 2.70, ligation: 44.4 ± 12.6 min, P = 0.043), CSF_OB (sham: 30.2 ± 2.67, ligation: 44.8 ± 7.47 min, P = 0.021), and CSF_PitR (sham: 30.2 ± 2.49, ligation: 41.3 ± 7.57 min, P = 0.021).Conclusion: The DCLN ligation in rats blocked CSF outflow into the nasal cavity and caused CSF retention.
著者
Yuriko Ishida Masaru Suzuki Hiroshi Horii Junichi Nakamura Munehiro Matsumoto Sho Nakakubo Takahiro Sato Ichizo Tsujino Ryo Morita Daisuke Abo Satoshi Konno
出版者
The Japanese Society of Internal Medicine
雑誌
Internal Medicine (ISSN:09182918)
巻号頁・発行日
pp.0015-22, (Released:2022-07-22)
参考文献数
23
被引用文献数
1

Pulmonary artery agenesis (PAA) is a rare congenital vascular anomaly usually diagnosed during infancy. We herein report a 67-year-old man with PAA manifesting as massive hemoptysis. Contrast-enhanced computed tomography of the chest revealed the diagnosis of PAA, which we speculated to have resulted in the present event. Detailed angiography provided more accurate information on the pulmonary vasculature and collateral circulation, which helped us plan tailored treatment. Although very rare, we must consider the possibility of PAA in adults with unexplained hemoptysis.