- 著者
-
Sandi SUFIANDI
Hiromichi OBARA
Huai-Che HSU
Shin ENOSAWA
Hiroshi MIZUNUMA
- 出版者
- The Japan Society of Mechanical Engineers
- 雑誌
- Journal of Biomechanical Science and Engineering (ISSN:18809863)
- 巻号頁・発行日
- pp.17-00421, (Released:2017-12-04)
- 参考文献数
- 34
- 被引用文献数
-
1
Improving the process of cell injection during hepatocyte transplantation requires an understanding of the causal relationships that shear, direct contact cells with a solid surface, and cell deformation have on cell viability loss. A linear shear model was used to model this loss of cell viability during their movement on a solid surface as part of the injection step of hepatocyte transplantation. Rat hepatocytes were studied under linear shear using two parallel plates, with a ”tight” condition that had a 25 μm gap, and a ”loose” gap condition with a > 25 μm gap, to determine the effects of cell deformation, and simulate cell viability loss during injection. Cell morphology and deformation were also observed using time-lapse images. Direct contact with a solid surface is deleterious for cells, and live cells became deformed under shear stress until they lost viability. The cell size could decrease or increase during deformation, and a loss of viability could occur due to a loss of membrane integrity or cell rupture. The space limitations in the tight gap could prevent cell expansion, which delayed the process of cell viability loss. In summary, preventing the direct contact of hepatocytes with a solid surface is recommended to improve the cell injection process during transplantation.