著者
Chanis PORNNUMPA Kazuki IWAOKA Naofumi AKATA Masahiro HOSODA Atsuyuki SORIMACHI Shinji TOKONAMI
出版者
日本保健物理学会
雑誌
保健物理 (ISSN:03676110)
巻号頁・発行日
vol.51, no.2, pp.115-121, 2016 (Released:2016-08-09)
参考文献数
27
被引用文献数
4

Namie Town, Fukushima Prefecture was instituted as an evacuation zone and a controlled area after the Fukushima Daiichi Nuclear Power Plant accident in April, 2011 which immediately resulted in a significant amount of radionuclides leakage to the environment. In this study, a car-borne survey utilizing a NaI(Tl) scintillation survey meter was carried out along ordinary roads and forest areas in Namie Town from September 29th to October 1st, 2011 to measure the absorbed dose rate by gamma-rays from 137Cs (T1/2: 30.05 y) and 134Cs (T1/2: 2.04 y) for the estimation of the radiation levels over long periods of time. The similar surveys were conducted again on August 22nd-24th, 2014 and September 14th-16th, 2015 using a NaI(Tl) scintillation spectrometer. The ratios of data obtained from urban areas to total surveyed areas in the same measurements were 27%, 34% and 48% in 2011, 2014 and 2015, respectively. The ratios of those measured from forest areas and mountain regions were 73%, 66% and 52% in 2011, 2014 and 2015, respectively. The absorbed dose rates in air obtained from these surveys were used to draw dose rate distribution maps to monitor the variation of the dose rates, and the distribution was found to be heterogeneous. The maximum value, minimum value and geometric mean of the absorbed dose rates in air for 2011 were estimated to be 47.6, 0.15 and 3.7 μGy h-1, respectively. The values for 2014 were estimated to be 5.8, 0.09 and 1.2 μGy h-1, respectively. In 2015, the values were estimated to be 5.6, 0.05 and 0.9 μGy h-1, respectively. The annual effective doses in 2014 and 2015 dropped by 66% and 75% from 2011, respectively. The annual effective doses estimated in 2014 and 2015 were lower than the annual effective dose limit of 20 mSv recommended by the Japanese government for an evacuation directive lift in the prepared area.
著者
Masahiro HOSODA Kazumasa INOUE Mitsuaki OKA Yasutaka OMORI Kazuki IWAOKA Shinji TOKONAMI
出版者
日本保健物理学会
雑誌
保健物理 (ISSN:03676110)
巻号頁・発行日
vol.51, no.1, pp.41-50, 2016 (Released:2016-07-06)
参考文献数
50
被引用文献数
2 25

Many nuclear facilities are located within Aomori Prefecture, Japan. However, no detailed dose rate distribution map of Aomori Prefecture, including its mountain regions has been reported since the Fukushima Daiichi Nuclear Power Plant accident. A car-borne survey which used a 3-in × 3-in NaI(Tl) scintillation spectrometer was carried out throughout the prefecture for the purposes of making a dose distribution map and estimating the annual external dose. The average absorbed dose rate in air and the annual effective dose were found to be 22 ± 5 nGy h-1 and 0.20 ± 0.08 mSv, respectively. These average values for all of Aomori Prefecture were respectively 44% and 59% of the nationwide average values. The average values with standard deviations of activity concentrations in soil of 40K, 238U and 232Th were 234 ± 148, 15 ± 6, 12 ± 6 Bq kg-1, respectively. The average values of contributions of 40K, 238U and 232Th to absorbed dose rates in air were 39%, 29% and 32%, respectively. The contributions of 134Cs and 137Cs to the absorbed dose rates in air were judged to be negligible.