著者
Takashi KAMEDA Kazuo OHKUMA Nozomu ISHII Natsuki SANO Hideo OGURA Kazuto TERADA
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
vol.31, no.5, pp.856-862, 2012-10-02 (Released:2012-10-02)
参考文献数
13
被引用文献数
3 5 4

Magnetic fields can represent a health problem, especially low frequency electromagnetic fields sometimes induced by electric current in metallic objects worn or used in or on the body (as opposed to high frequency electromagnetic fields that produce heat). Electric toothbrushes are widely used because of their convenience, but the electric motors that power them may produce electromagnetic waves. In this study, we showed that electric toothbrushes generate low frequency (1-2000 Hz) magnetic fields and induce electric current in dental appliances (e. g. orthodontic and prosthetic appliances and dental implants). Current induced by electric toothbrushes might be dependent on the quantity and types of metals used, and the shape of the appliances. Furthermore, these induced currents in dental appliances could impact upon human oral health, producing pain and discomfort.
著者
Takashi KAMEDA Shunya OKA Jun-ichi IGAWA Makoto SAKAMOTO Kazuto TERADA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
vol.41, no.1, pp.167-183, 2022-01-25 (Released:2022-02-01)
参考文献数
26
被引用文献数
2

Coronavirus disease pandemic has led to a shortage of disinfectant alcohol (DA; 76.9–81.4% ethanol solution) in Japan. This study investigated the availability of hypochlorous acid (HA) as an alternative disinfectant to DA in clinical environment. HA is a safe and economical disinfectant with a broad antibacterial spectrum and low risk of hand irritation, which is used worldwide. In this study, HA and sodium hypochlorite solution (SH) were degraded over time and the degradation was accelerated by temperature and lighting. Results of bactericidal effects of HA revealed that the realistic effective concentration should be 200 ppm. Compared with DA, the dental carbon steel burs were more severely rusted by SH and HA. These results indicated that high concentration of HA generated on-site could be an effective and safe disinfectant for use immediately after generation with consideration of object materials in clinical environment, as an alternative to DA.
著者
Takashi KAMEDA Shunya OKA Jun-ichi IGAWA Makoto SAKAMOTO Kazuto TERADA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-146, (Released:2021-10-22)
参考文献数
26
被引用文献数
2

Coronavirus disease pandemic has led to a shortage of disinfectant alcohol (DA; 76.9–81.4% ethanol solution) in Japan. This study investigated the availability of hypochlorous acid (HA) as an alternative disinfectant to DA in clinical environment. HA is a safe and economical disinfectant with a broad antibacterial spectrum and low risk of hand irritation, which is used worldwide. In this study, HA and sodium hypochlorite solution (SH) were degraded over time and the degradation was accelerated by temperature and lighting. Results of bactericidal effects of HA revealed that the realistic effective concentration should be 200 ppm. Compared with DA, the dental carbon steel burs were more severely rusted by SH and HA. These results indicated that high concentration of HA generated on-site could be an effective and safe disinfectant for use immediately after generation with consideration of object materials in clinical environment, as an alternative to DA.