著者
Nao TAKAHASHI Hiroyasu KUROKAWA Kengo WAKAMATSU Eizo HIROKANE Toshiki TAKAMIZAWA Masashi MIYAZAKI Nobuya KITAHARA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-154, (Released:2021-09-23)
参考文献数
27
被引用文献数
7

This study investigated the bonding performance of two different types of resin cements to computer-aided design/computer-aided manufacturing (CAD/CAM) composite blocks based on the shear bond strength (SBS) test. A silane-containing self-adhesive resin cement (Panavia SA Cement Universal) and resin luting cement (Block HC Cem) with a primer, were used. Specimens were fabricated from three different types of CAD/CAM composite blocks, and their surfaces were blasted with alumina. Resin cements were bonded to the specimens, and their SBSs were measured after 15 min, 24 h, and after being subjected to thermal cycling for 10,000 and 30,000 cycles. Three-way ANOVA for bond strength revealed that CAD/CAM composite block, resin cement and storage time significantly influenced the SBS values, and the three-way interactions between the evaluated factors, and all the interactions were significant. It was concluded that the bonding performance of resin cements to CAD/CAM composite blocks were material and storage period dependent.
著者
Hajime OOUCHI Toshiki TAKAMIZAWA Tomohiko TAMURA Ryo ISHII Akimasa TSUJIMOTO Masashi MIYAZAKI Nobuya KITAHARA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2020-381, (Released:2021-04-20)
参考文献数
28
被引用文献数
6

This study investigates the flexural properties, Knoop hardness number (KHN), and wear behavior of computer-aided design and computer-aided manufacturing (CAD/CAM) resin blocks and compares these values with those of conventional resin composites for direct restoration (RCDs). Four CAD/CAM resin blocks and two RCDs are compared. Ten specimens per material are used to obtain the flexural properties according to ISO 6872 specifications, and five specimens per material are used for KHN measurement. For sliding impact wear testing, twelve specimens are prepared. Confocal laser scanning microscopy (LSM) is used to determine maximum facet depth and volume loss. Polished material surfaces and worn surfaces after wear testing are observed using scanning electron microscopy and LSM. While measured flexural properties and KHN are found to be material-dependent, CAD/CAM resin blocks exhibit higher wear resistance than RCDs. CAD/CAM resin blocks polymerized at high-pressure and high-temperature are found to exhibit wear behaviors far superior to those of RCDs.