著者
Nao TAKAHASHI Hiroyasu KUROKAWA Kengo WAKAMATSU Eizo HIROKANE Toshiki TAKAMIZAWA Masashi MIYAZAKI Nobuya KITAHARA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-154, (Released:2021-09-23)
参考文献数
27
被引用文献数
7

This study investigated the bonding performance of two different types of resin cements to computer-aided design/computer-aided manufacturing (CAD/CAM) composite blocks based on the shear bond strength (SBS) test. A silane-containing self-adhesive resin cement (Panavia SA Cement Universal) and resin luting cement (Block HC Cem) with a primer, were used. Specimens were fabricated from three different types of CAD/CAM composite blocks, and their surfaces were blasted with alumina. Resin cements were bonded to the specimens, and their SBSs were measured after 15 min, 24 h, and after being subjected to thermal cycling for 10,000 and 30,000 cycles. Three-way ANOVA for bond strength revealed that CAD/CAM composite block, resin cement and storage time significantly influenced the SBS values, and the three-way interactions between the evaluated factors, and all the interactions were significant. It was concluded that the bonding performance of resin cements to CAD/CAM composite blocks were material and storage period dependent.
著者
Tatsuya IIJIMA Hiroyasu KUROKAWA Toshiki TAKAMIZAWA Eizo HIROKANE Nao TAKAHASHI Kengo WAKAMATSU Shunichi SUDA Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-011, (Released:2021-06-30)
参考文献数
40

The purpose of this study was to investigate the ability of polishing paste containing surface pre-reacted glass-ionomer (S-PRG) filler to prevent acidic attack on tooth enamel surfaces. Resin composites were filled in the standardized cavities and finished with silicon carbide paper. These specimens were divided into three groups: the unpolished “control” group, the “PRG” group polished with S-PRG paste, and the “DDP” group polished with diamond-containing polishing paste. Following polishing, the specimens were immersed in a lactic acid buffer solution for 28 days. Optical coherence tomography (OCT) signals were measured to obtain the signal intensity and width at 1/e2 at selected locations on the enamel surface adjacent to the restoration. Although signal intensity significantly increased in all groups, widths at 1/e2 did not change significantly in the PRG group. For both the control and DDP groups, signal intensity and width at 1/e2 increased and decreased over time, respectively.