著者
Aika Okazawa Mami Iima Masako Kataoka Ryosuke Okumura Sachiko Takahara Tomotaka Noda Taro Nishi Takayoshi Ishimori Yuji Nakamoto
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2022-0056, (Released:2023-05-26)
参考文献数
17

Purpose: We aimed to investigate the diagnostic feasibility of an adjusted diffusion-weighted imaging (DWI) lexicon using multiple b values to assess breast lesions according to DWI-based breast imaging reporting and data system (BI-RADS).Methods: This Institutional Review Board (IRB)-approved prospective study included 127 patients with suspected breast cancer. Breast MRI was performed using a 3T scanner. Breast DW images were acquired using five b-values of 0, 200, 800, 1000, and 1500 s/mm2 (5b-value DWI) on 3T MRI. Two readers independently assessed lesion characteristics and normal breast tissue using DWI alone (5b-value DWI and 2b-value DWI with b = 0 and 800 s/mm2) according to DWI-based BI-RADS and in combination with the standard dynamic contrast-enhanced images (combined MRI). Interobserver and intermethod agreements were assessed using kappa statistics. The specificity and sensitivity of lesion classification were evaluated.Results: Ninety-five breast lesions (39 malignant and 56 benign) were evaluated. Interobserver agreement for lesion assessment on 5b-value DWI was very good (k ≥ 0.82) for DWI-based BI-RADS categories, lesion type, and mass characteristics; good (k = 0.75) in breast composition; and moderate (k ≥ 0.44) in background parenchymal signal (BPS) and non-mass distribution. Intermethod agreement between assessments performed using either 5b-value DWI or combined MRI was good-to-moderate (k = 0.52–0.67) for lesion type; moderate (k = 0.49–0.59) for DWI-based BI-RADS category and mass characteristics; and fair (k = 0.25–0.40) for mass shape, BPS, and breast composition. The sensitivity and positive predictive values (PPVs) for 5b-value DWI were 79.5%, 84.6% and 60.8%, 61.1% for each reader, respectively; 74.4%, 74.4% and 63.0%, 61.7% for 2b-value DWI; and 97.4%, 97.4% and 73.1%, 76.0% for combined MRI. The specificity and negative predictive values (NPVs) were 64.3%, 62.5% and 81.8%, 85.4% for 5b-value DWI; 69.6%, 67.9% and 79.6%, 79.2% for 2b-value DWI; and 75.0%, 78.6% and 97.7%, 97.8% for combined MRI.Conclusion: Good observer agreement was observed in the 5b-value DWI. The 5b-value DWI based on multiple b-values might have the potential to complement the 2b-value DWI; however, their diagnostic performance tended to be inferior to that of combined MRI for the characterization of breast tumors.