著者
Maya Honda Mami Iima Masako Kataoka Yasuhiro Fukushima Rie Ota Akane Ohashi Masakazu Toi Yuji Nakamoto
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2022-0060, (Released:2022-08-03)
参考文献数
35
被引用文献数
2

Purpose: To investigate whether intravoxel incoherent motion (IVIM) and/or non-Gaussian diffusion parameters are associated with distant disease-free survival (DDFS) in patients with invasive breast cancer.Methods: From May 2013 to March 2015, 101 patients (mean age 60.0, range 28–88) with invasive breast cancer were evaluated prospectively. IVIM parameters (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion parameters (theoretical apparent diffusion coefficient [ADC] at a b value of 0 s/mm2 [ADC0] and kurtosis [K]) were estimated using a diffusion-weighted imaging series of 16 b values up to 2500 s/mm2. Shifted ADC values (sADC200–1500) and standard ADC values (ADC0–800) were also calculated. The Kaplan–Meier method was used to generate survival analyses for DDFS, which were compared using the log-rank test. Univariable Cox proportional hazards models were used to assess any associations between each parameter and distant metastasis-free survival.Results: The median observation period was 80 months (range, 35–92 months). Among the 101 patients, 12 (11.9%) developed distant metastasis, with a median time to metastasis of 79 months (range, 10–92 months). Kaplan–Meier analysis showed that DDFS was significantly shorter in patients with K > 0.98 than in those with K ≤ 0.98 (P = 0.04). Cox regression analysis showed a marginal statistical association between K and distant metastasis-free survival (P = 0.05).Conclusion: Non-Gaussian diffusion may be associated with prognosis in invasive breast cancer. A higher K may be a marker to help identify patients at an elevated risk of distant metastasis, which could guide subsequent treatment.
著者
Hitomi Numamoto Koji Fujimoto Kanae Kawai Miyake Yasutaka Fushimi Sachi Okuchi Rimika Imai Hiroki Kondo Tsuneo Saga Yuji Nakamoto
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2023-0102, (Released:2023-11-10)
参考文献数
20
被引用文献数
1

Purpose: To compare image distortion and reproducibility of quantitative values between reverse encoding distortion correction (RDC) diffusion-weighted imaging (DWI) and conventional DWI techniques in a phantom study and in healthy volunteers.Methods: This prospective study was conducted with the approval of our institutional review board. Written informed consent was obtained from each participant. RDC-DWIs were created from images obtained at 3T in three orthogonal directions in a phantom and in 10 participants (mean age, 70.9 years; age range, 63–83 years). Images without distortion correction (noDC-DWI) and those corrected with B0 (B0c-DWI) were also created. To evaluate distortion, coefficients of variation were calculated for each voxel and ROIs were placed at four levels of the brain. To evaluate the reproducibility of apparent diffusion coefficient (ADC) measurements, intra- and inter-scan variability (%CVADC) were calculated from repeated scans of the phantom. Analysis was performed using Wilcoxon signed-rank test with Bonferroni correction, and P < 0.05 was considered statistically significant.Results: In the phantom, distortion was less in RDC-DWI than in B0c-DWI (P < 0.006), and was less in B0c-DWI than in noDC-DWI (P < 0.006). Intra-scan %CVADC was within 1.30%, and inter-scan %CVADC was within 2.99%. In the volunteers, distortion was less in RDC-DWI than in B0c-DWI in three of four locations (P < 0.006), and was less in B0c-DWI than in noDC-DWI (P < 0.006). At the middle cerebellar peduncle, distortion was less in RDC-DWI than in noDC-DWI (P < 0.006), and was less in noDC-DWI than in B0c-DWI (P < 0.0177).Conclusion: In both the phantom and in volunteers, distortion was the least in RDC-DWI than in B0c-DWI and noDC-DWI.
著者
Aika Okazawa Mami Iima Masako Kataoka Ryosuke Okumura Sachiko Takahara Tomotaka Noda Taro Nishi Takayoshi Ishimori Yuji Nakamoto
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2022-0056, (Released:2023-05-26)
参考文献数
17

Purpose: We aimed to investigate the diagnostic feasibility of an adjusted diffusion-weighted imaging (DWI) lexicon using multiple b values to assess breast lesions according to DWI-based breast imaging reporting and data system (BI-RADS).Methods: This Institutional Review Board (IRB)-approved prospective study included 127 patients with suspected breast cancer. Breast MRI was performed using a 3T scanner. Breast DW images were acquired using five b-values of 0, 200, 800, 1000, and 1500 s/mm2 (5b-value DWI) on 3T MRI. Two readers independently assessed lesion characteristics and normal breast tissue using DWI alone (5b-value DWI and 2b-value DWI with b = 0 and 800 s/mm2) according to DWI-based BI-RADS and in combination with the standard dynamic contrast-enhanced images (combined MRI). Interobserver and intermethod agreements were assessed using kappa statistics. The specificity and sensitivity of lesion classification were evaluated.Results: Ninety-five breast lesions (39 malignant and 56 benign) were evaluated. Interobserver agreement for lesion assessment on 5b-value DWI was very good (k ≥ 0.82) for DWI-based BI-RADS categories, lesion type, and mass characteristics; good (k = 0.75) in breast composition; and moderate (k ≥ 0.44) in background parenchymal signal (BPS) and non-mass distribution. Intermethod agreement between assessments performed using either 5b-value DWI or combined MRI was good-to-moderate (k = 0.52–0.67) for lesion type; moderate (k = 0.49–0.59) for DWI-based BI-RADS category and mass characteristics; and fair (k = 0.25–0.40) for mass shape, BPS, and breast composition. The sensitivity and positive predictive values (PPVs) for 5b-value DWI were 79.5%, 84.6% and 60.8%, 61.1% for each reader, respectively; 74.4%, 74.4% and 63.0%, 61.7% for 2b-value DWI; and 97.4%, 97.4% and 73.1%, 76.0% for combined MRI. The specificity and negative predictive values (NPVs) were 64.3%, 62.5% and 81.8%, 85.4% for 5b-value DWI; 69.6%, 67.9% and 79.6%, 79.2% for 2b-value DWI; and 75.0%, 78.6% and 97.7%, 97.8% for combined MRI.Conclusion: Good observer agreement was observed in the 5b-value DWI. The 5b-value DWI based on multiple b-values might have the potential to complement the 2b-value DWI; however, their diagnostic performance tended to be inferior to that of combined MRI for the characterization of breast tumors.
著者
Azusa Sakurama Yasutaka Fushimi Satoshi Nakajima Akihiko Sakata Takuya Hinoda Sonoko Oshima Sayo Otani Krishna Pandu Wicaksono Wei Liu Takakuni Maki Tomohisa Okada Ryosuke Takahashi Yuji Nakamoto
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0065, (Released:2021-10-01)
参考文献数
40

Purpose: To compare reliability and elucidate clinical application of magnetization-prepared rapid gradient-echo (MPRAGE) with 9-fold acceleration by using wave-controlled aliasing in parallel imaging (Wave-CAIPI 3 × 3) in comparison to conventional MPRAGE accelerated by using generalized autocalibrating partially parallel acquisition (GRAPPA) 2 × 1.Methods: A total of 26 healthy volunteers and 33 patients were included in this study. Subjects were scanned with two MPRAGEs, GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 acquired in 5 min 21 s and 1 min 42 s, respectively, on a 3T MR scanner. Healthy volunteers underwent additional two MPRAGEs (CAIPI 3 × 3 and GRAPPA 3 × 3). The image quality of the four MPRAGEs was visually evaluated with a 5-point scale in healthy volunteers, and the SNR of four MPRAGEs was also calculated by measuring the phantom 10 times with each MPRAGE. Based on the results of the visual evaluation, voxel-based morphometry (VBM) analyses, including subfield analysis, were performed only for GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. Correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was assessed.Results: In visual evaluations, scores for MPRAGE GRAPPA 2 × 1 (mean rank: 4.00) were significantly better than those for Wave-CAIPI 3 × 3 (mean rank: 3.00), CAIPI 3 × 3 (mean rank: 1.83), and GRAPPA 3 × 3 (mean rank: 1.17), and scores for Wave-CAIPI 3×3 were significantly better than those for CAIPI 3 × 3 and GRAPPA 3 × 3. Image noise was evident at the center for additional MPRAGE CAIPI 3 × 3 and GRAPPA 3 × 3. The correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was higher than 0.85 in all VOIs except globus pallidus. Subfield analysis of hippocampus also showed a high correlation between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3.Conclusion: MPRAGE Wave-CAIPI 3 × 3 shows relatively better contrast, despite of its short scan time of 1 min 42 s. The volumes derived from automated segmentation of MPRAGE Wave-CAIPI are considered to be reliable measures.
著者
Satoshi Otani Aki Kido Yuki Himoto Akihiko Sakata Tomoaki Otani Ryo Kuwahara Yusaku Moribata Naoko Nishio Ryo Yajima Kyoko Nakao Yasuhisa Kurata Sachiko Minamiguchi Masaki Mandai Yuji Nakamoto
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0003, (Released:2021-09-03)
参考文献数
26
被引用文献数
4

Purpose: To compare the diagnostic performance of dynamic contrast-enhanced-MR (DCE-MR) and delayed contrast-enhanced (CE)-MRI added to unenhanced MRI, including diffusion weighted image (DWI) for differentiating malignant adnexal tumors, conducting a retrospective blinded image interpretation study.Methods: Data of 80 patients suspected of having adnexal tumors by ultrasonography between April 2008 and August 2018 were used for the study. All patients had undergone preoperative MRI and surgical resection at our institution. Four radiologists (two specialized in gynecological radiology and two non-specialized) were enrolled for blinded review of the MR images. A 3-point scale was used: 0 = benign, 1 = indeterminate, and 2 = malignant. Three imaging sets were reviewed: Set A, unenhanced MRI including DWI; Set B, Set A and delayed CE-T1WI; and Set C, Set A and DCE-MRI. Imaging criteria for benign and malignant tumors were given in earlier reports. The diagnostic performance of the three imaging sets of the four readers was calculated. Their areas under the curve (AUCs) were compared using the DeLong method.Results: Accuracies of Set B were 81%–88%. Those of Set C were 81%–85%. The AUCs of Set B were 0.83 and 0.89. Those of Set C were 0.81–0.86. For two readers, Set A showed lower accuracy and AUC than Set B/Set C (less than 0.80), although those were equivalent in other readers. No significant difference in AUCs was found among the three sequence sets. Intrareader agreement was moderate to almost perfect in Sets A and B, and substantial to almost perfect in Set C.Conclusion: DCE-MR showed no superiority for differentiating malignant adnexal tumors from benign tumors compared to delayed CE-T1WI with conventional MR and DWI.
著者
Taku Sugawa Takaaki Murakami Daisuke Yabe Riko Kashima Makiko Tatsumi Shinobu Ooshima Erina Joo Keiko Wada Atsushi Yoshizawa Toshihiko Masui Yuji Nakamoto Yuki Yamauchi Yuzo Kodama Yoshiki Iemura Masahito Ogura Akihiro Yasoda Nobuya Inagaki
出版者
The Japanese Society of Internal Medicine
雑誌
Internal Medicine (ISSN:09182918)
巻号頁・発行日
pp.1173-18, (Released:2018-08-10)
参考文献数
22
被引用文献数
11

The delayed diagnosis of insulinoma remains a clinical issue. One of the main causes of such a delay is hypoglycemia unawareness. A 53-year-old woman fell unconscious during postprandial exercises. Flash glucose monitoring (FGM) systems revealed glucose profiles with fasting hypoglycemia, which facilitated the clinical diagnosis of insulinoma even though she was unaware of her hypoglycemia. The preoperative comparison of the blood glucose values provided by FGM with those obtained from capillary blood were consistent. Thus, FGM may have potential utility in revealing the presence of insulinoma-induced hypoglycemia.