著者
Tommaso VEZZOSI Roberto GHINELLI Paolo FERRARI Francesco PORCIELLO
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.20-0622, (Released:2021-02-09)
被引用文献数
3

This study reports the echocardiographic reference intervals in the American Staffordshire Terrier (AST). The echocardiographic variables obtained in 57 healthy adult AST were compared with published data from the general canine population and other breeds. In the AST, the left ventricular volumes were lower than values reported in Boxers and Dobermans (P<0.0001), but higher than in small breeds (P<0.0001). The left ventricular ejection fraction was higher than Boxers and Dobermans (P<0.0001), but lower than small breed dogs (P=0.027). The aortic peak velocity values were similar to Boxers (P=0.55) but higher than the general canine population (P<0.0001). The reference intervals presented in this study are clinically useful for an accurate echocardiographic interpretation and screening in the AST.
著者
Federica MARCHESOTTI Tommaso VEZZOSI Rosalba TOGNETTI Francesca MARCHETTI Valentina PATATA Barbara CONTIERO Eric ZINI Oriol DOMENECH
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.19-0240, (Released:2019-10-14)
被引用文献数
13

Left atrial enlargement (LAE) is a well-known negative prognostic factor in dogs with myxomatous mitral valve disease (MMVD). Left atrial-to-aortic root ratio (LA/Ao) is the most commonly used method to evaluate left atrial (LA) size in dogs, while the left atrial anteroposterior diameter (LAD) has been proposed as an additional measurement of LA size in different species. The aim of this study was to establish a normal reference range of LAD normalized to body weight (LADn) in dogs using allometric scales, and to evaluate the agreement between LADn and LA/Ao in the detection of LAE in dogs with MMVD. This was a retrospective, multicenter, observational study. We included 330 healthy dogs, 30 dogs with MMVD in ACVIM stage B1, 30 dogs in ACVIM stage B2, and 30 dogs in ACVIM stage C. The reference range for the LAD, depending on body weight, was between 16.91 mm and 49.68 mm. The reference range for the LADn in healthy dogs was between 10.49 and 15.72. LADn was significantly greater in dogs with MMVD compared to healthy dogs, and a significant difference in LADn was noted between different ACVIM stages (P<0.001). The most accurate cut-off value of LADn to differentiate between dogs in groups B2 and C was 20.3 (sensitivity, 83.3%; specificity, 83.3%). There was a misclassification rate of 37% between LADn and LA/Ao in the detection of LAE in group B1. This study provides a normal reference range for LAD in dogs, which can be used as an additional tool to assess LAE in dogs with MMVD.
著者
Cristina CARNABUCI Rosalba TOGNETTI Tommaso VEZZOSI Federica MARCHESOTTI Valentina PATATA Oriol DOMENECH
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.18-0699, (Released:2019-03-11)
被引用文献数
6

In canine electrocardiography, the reference interval of the ventricular mean electrical axis (MEA) is between +40° and +100°. MEA values in dogs can be influenced by the patient position as well as by the shape of the thorax. The aim of this study was to evaluate the MEA in healthy Doberman Pinschers, hypothesizing that some present a left shift of the MEA. In this retrospective study, 41 healthy, client-owned Doberman Pinschers were included. Echocardiography and standard six-lead ECG examination were performed in all dogs. The MEA was calculated using the isoelectric method. The morphology of the QRS complex and the Q/R ratio in lead II were also evaluated. The median MEA was +45° and ranged from –45° to +90°. MEA was deviated in 16/41 dogs (39%), all presenting a left axis deviation (range, –45° to +30°). Age was significantly associated with the MEA (P=0.008), showing a negative linear correlation. A deep Q wave in lead II was present in 26/41 (63%) dogs. The Q/R ratio was higher in dogs presenting left shift of the MEA (0.66; range, 0.28–1.35) in comparison to dogs with a MEA within reference range (0.44; range, 0.04–0.73; P<0.001). In conclusion, a significant number of healthy Doberman Pinschers present a left shift of the MEA compare to the reference range, and dogs with MEA deviation show a higher Q/R ratio in lead II. This data should be considered when electrocardiographic evaluation is performed in Doberman Pinschers.