著者
Tomohiro Oba Hiroaki Iwase Yoshitake Oshima Junya Miyazaki Kojiro Ishii
出版者
The Japanese Association of Rehabilitation Medicine
雑誌
Progress in Rehabilitation Medicine (ISSN:24321354)
巻号頁・発行日
vol.2, pp.20170016, 2017 (Released:2017-12-27)
参考文献数
26
被引用文献数
1 1

Objective: This study investigated the optimum conditions for obtaining valid step-count measurements for patients with abnormal gait. Methods: Subjects comprised 61 hospitalized patients with abnormal gait. Four different devices were tested: Active Style Pro (AS), Walking Style (WS), Lifecorder PLUS, and Steps. The same device type was attached to the waist on both the affected and the unaffected side. Patients then walked 25 m at a comfortable speed. This test was repeated four times, once for each device. The measurement error (ME) and walking parameters (gait velocity, step length, and cadence) were calculated from the test data. ME scores smaller than 3% and 10% were classified as valid: scores above these standards were classified as invalid. Walking parameter values that identified the invalid group with a specificity of 0.95 were set as the cut-off velocity (COV), the cut-off step length (COS), and the cut-off cadence. Sensitivity values >0.40 and positive predictive values >80% were then set as necessary conditions. Results: COV values were 0.90 m/s (AS on the unaffected side at 3% ME and AS on the affected side or the unaffected side at 10% ME), 0.92 m/s (WS on the unaffected side at 10% ME), and 0.98 m/s (WS on the affected side at 3% ME). COS values were 0.50 m (AS on the affected side at 10% ME) and 0.52 m (AS on the unaffected side at 3% ME). Conclusion: The most accurate measurements were obtained using AS attached to the unaffected side with a gait velocity of >0.90 m/s.
著者
Shintaro Sato Kenji Kusano Hiroki Ohta Yuta Tsukahara Gen Kida Emiri Tsumiyama Tomotaka Nishizawa Tomohiro Oba Rie Kawabe Hideaki Yamakawa Keiichi Akasaka Masako Amano Tamiko Takemura Hidekazu Matsushima
出版者
The Japanese Society of Internal Medicine
雑誌
Internal Medicine (ISSN:09182918)
巻号頁・発行日
pp.5674-20, (Released:2021-02-22)
参考文献数
18
被引用文献数
1

A 60-year-old Japanese woman was admitted to our hospital with a fever and shortness of breath occurring immediately after using hairspray. Chest high-resolution computed tomography (HRCT) showed ground-glass opacities (GGOs) predominantly distributed around the bronchovascular bundles, and a pathological evaluation by a transbronchial lung cryobiopsy (TBLC) revealed fibrotic non-specific interstitial pneumonia (f-NSIP). Her symptoms disappeared without the use of corticosteroids, and GGO on HRCT improved markedly over time. This case suggests that a pathological evaluation by a TBLC for lung injury due to inhalation pathogen exposure may provide a more accurate diagnosis and a better understanding of the pathology from bronchial to interstitial lesions than transbronchial lung biopsy.