著者
Tomoya IIZUKA Ryohei NISHIMURA
出版者
公益社団法人 日本獣医学会
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.14-0549, (Released:2015-01-29)
被引用文献数
7

Context-sensitive half-times (CSHTs) of fentanyl in dogs were determined using pharmacokinetic models reported by Murphy et al. and Sano et al., and compared with a human model. The CSHT was defined as the time required for a 50% decrease in drug concentration in the central compartment after the termination of infusion. Although CSHTs increased gradually as the infusion time increased, the CSHTs in dogs were shorter than those in humans. The CSHTs at steady-state were 31.3 and 69.2 min in dogs, and 306.5 min in humans. The CSHTs of fentanyl in dogs are apparently shorter than those in humans; therefore, a continuous infusion of fentanyl may be a rational regimen in dogs, even if duration of infusion is extended.
著者
Tomoya IIZUKA Kenichi MASUI Hideko KANAZAWA Ryohei NISHIMURA
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.17-0468, (Released:2018-07-17)
被引用文献数
1

The relationships between propofol plasma concentrations and the pharmacodynamic endpoints may differ according to a type of airway device. To clarify these relationships in different airway devices would be useful to avoid the complication such as apnea and intraoperative awareness. The aim of this study was to investigate the influence of difference of airway device on propofol requirement during maintenance of anesthesia in dogs. We compared the influence of airway devices on the plasma propofol concentrations for apnea, response to mechanical ventilation, and response to airway device between endotracheal tube (ETT) and supraglottic airway device (SGAD) in Beagles. The pharmacodynamic effects were repeatedly assessed at varying propofol concentrations. The plasma concentrations (mean ± SD) of propofol in the ETT and SGAD groups were 10.2 ± 1.8 and 10.9 ± 2.4 μg/ml for apnea (P=0.438), 7.9 ± 1.2 and 7.4 ± 1.5 μg/ml for response to mechanical ventilation (P=0.268), and 5.2 ± 0.7 and 5.4 ± 1.5 μg/ml for response to airway device (P=0.580), respectively. Required propofol concentration during maintenance of anesthesia may be similar between ETT and SGAD. Without moderate to strong stimuli such as airway device insertion or painful stimulation during surgery, the type of airway device may have little impact on required propofol concentration during maintenance of anesthesia in dogs.