- 著者
-
寺田 英嗣
牧野 洋
今瀬 憲司
- 出版者
- 公益社団法人精密工学会
- 雑誌
- 精密工学会誌 (ISSN:09120289)
- 巻号頁・発行日
- vol.63, no.11, pp.1609-1613, 1997-11-05
- 参考文献数
- 5
- 被引用文献数
-
2
2
It is important to eliminate the backlash and to reduce inertia for high accuracy linear motion system. For this reason, the trochoid cam rack has been developed. The profile undercut must be avoided to satisfy the required performance. So this rack profile is ground using trochoid curve loci. In this report, the motion principle has been analyzed, and it becomes clear that there is the optimal value of rack profile offset factor which affects on pressure angle and radius of curvature. Also, roller diameter and tooth height affects on those characteristics. The optimal cam rack without profile undercut is designed using the selected each design factor. The prototype cam rack system using optimal design value is made and tested. It is proved that the system has high positioning accuracy without backlash.