著者
濁川 直寛 浅香 美治 長谷部 雅伸
出版者
日本建築学会
雑誌
日本建築学会技術報告集 (ISSN:13419463)
巻号頁・発行日
vol.23, no.55, pp.851-856, 2017

A simple seismic isolation system by leveraging buoyancy has been devised for spread foundation structures. Through dynamic centrifuge tests, it is shown experimentally that a sliding isolation effect arises during seismic loading if a buoyant force of appropriate magnitude is applied to the base of the foundation. It is confirmed that seismic isolation performance tends to improve as the buoyancy-to-weight ratio increases. Performance when the buoyancy-to-weight ratio is 90% or more is particularly good, and the maximum response acceleration of a structure can be reduced to below 100 cm/s<sup>2</sup> against a sinusoidal wave with a maximum acceleration of 500 cm/s<sup>2</sup>.
著者
時松 孝次 新井 洋 浅香 美治
出版者
日本建築学会
雑誌
日本建築学会構造系論文集 (ISSN:13404202)
巻号頁・発行日
vol.62, no.491, pp.37-45, 1997
被引用文献数
12 3

Microtremor measurements are conducted in the Sumiyoshi area, Kobe city, using array of sensors together with conventional measurements using one station. The F-k and H/V spectral analyses of micro-tremors result in two-dimensional shear wave structure down to the bedrock. The distribution of peak ground motions during the 1995 Hyogoken-Nanbu earthquake is then estimated using one-dimensional effective stress analyses. The estimated values in the heavily damaged area are larger than those in the other area, indicating that one-dimensional site amplification characteristics had a significant effect on the damage distribution of buildings.