- 著者
-
野村 修一
三浦 順市
金子 康弘
星野 寿幸
石岡 靖
- 出版者
- 社団法人 日本補綴歯科学会
- 雑誌
- 日本補綴歯科学会雑誌 (ISSN:03895386)
- 巻号頁・発行日
- vol.35, no.4, pp.789-793, 1991-08-01 (Released:2010-08-10)
- 参考文献数
- 13
This study aims to applicate the Biometric impression trays for Japanese edentulous patients. A hundred (fifity males and fifity females) Japanese bucco-lingual breadth (BLB) s of the dentulous alveolar process were measured on maxillary study casts by the three dimensional coordinate measuring machine.Results:1. Average measurements (mm) and standard deviations (mm) were as follows. Central incisor; 5.7±1.15, canine 7.5±1.41, first premolar 10.7±1.07, second premolar 11.4±1.37, first molar 13.4±1.25 and second molar 12.3±1.33.2. Japanese average measurements were 0.5-1.0mm smaller in incisor and canine region, but 0.6-0.8 larger in premolar and molar region as compared with figures of Scottish that Watt had reported.3. Biometric tray of which design is based on the average BLB measurements will become a concrete guide to the breadth of the flange of complete upper dentures for Japanese.