著者
青柳 直子 喜久田 利弘 鰺坂 正秋 池山 尚岐 梅本 丈二 嶋村 知記
出版者
Japanese Society of Oral and Maxillofacial Surgeons
雑誌
日本口腔外科学会雑誌 (ISSN:00215163)
巻号頁・発行日
vol.54, no.3, pp.140-144, 2008-03-20 (Released:2011-04-22)
参考文献数
23
被引用文献数
1

An air-turbine handpiece is used for bone cutting and tooth dissection during extraction of an impacted lower third molar. However, subcutaneous emphysema and mediastinal emphysema may develop as advanced complications. Six patients had emphysema caused by the use of an air-turbine handpiece in our department during the last 10 years. Mediastinal emphysema developed in 3 patients. The route of the air was examined by CT scanning. The findings suggested that the air extended from a lingual sparse part of the extraction cavity to the sublingual space, submandibular space, masticator space, pterygomandibular space, lateral parapharyngeal space, carotid sheath, retropharyngeal space, and finally to the mediastinum. Since the pterygomandibular space communicates with the contralateral side, air easily invades this region.