著者
Ying Yang Kuanghui Xu Xiaofei Chen Jianping Ding Junping Shi Jie Li
出版者
Japanese Society for Magnetic Resonance in Medicine
雑誌
Magnetic Resonance in Medical Sciences (ISSN:13473182)
巻号頁・発行日
pp.mp.2021-0168, (Released:2022-06-07)
参考文献数
46
被引用文献数
3

Purpose: The Multi-echo Dixon (ME-Dixon) is a non-invasive quantitative MRI technique to diagnose non-alcoholic fatty liver disease (NAFLD). In this study, the hydrogen proton MR spectroscopy (1H-MRS) was used as a reference to explore the accuracy of the ME-Dixon technique in evaluating hepatic steatosis in NAFLD patients after ingesting formulated food and its correlation with changes in clinical indicators.Methods: Twenty-seven patients with NAFLD were enrolled. Fifteen patients completed 12 weeks of treatment with prebiotics and dietary fiber. In addition, abdominal MRI scans and blood tests were performed before and after treatment. The MRI-proton density fat fraction (MRI-PDFF) and MRS-PDFF were measured using the ME-Dixon and 1H-MRS techniques. The Bland–Altman method and Pearson correlation analysis were used to test the consistency of the two techniques for measuring the liver fat content and the changed values. Besides, correlation analysis was conducted between the MRI-PDFF value and metabolic indicators.Results: In the PDFF quantification of 42 person-times and the monitoring of the PDFF change in 15 patients under treatment, there was a good consistency and a correlation between MRI and MRS. At baseline, MRI-PDFF was positively correlated with insulin resistance index (HOMA-IR), fatty liver index (FLI), and liver enzymes. After treatment, the changes in MRI-PDFF were positively correlated with the recovery degree of FLI and liver enzymes.Conclusion: ME-Dixon has a good consistency and a correlation with MRS in quantifying the liver fat content and monitoring the treatment effect, which may be used as an accurate indicator for clinical monitoring of changes in the liver fat content.
著者
Jie Huang Jianping Ding
出版者
National Institute of Infectious Diseases, Japanese Journal of Infectious Diseases Editorial Committee
雑誌
Japanese Journal of Infectious Diseases (ISSN:13446304)
巻号頁・発行日
pp.JJID.2020.098, (Released:2020-05-29)
参考文献数
9
被引用文献数
1

The number of reported cases of the new coronavirus disease named “severe acute respiratory syndrome-coronavirus 2” (SARS-CoV-2) has increased since December 2019. The initial high-resolution computed tomography (HRCT) images of seven patients with diagnosed COVID-19 in the Affiliated Hospital of Hangzhou Normal University, China, were collected and analyzed. The study showed that all patients had close contact with COVID-19 patient and presented with fever. The initial white blood cell counts of all patients were normal. The percentage of lymphocytes decreased in three patients. In all seven patients with COVID-19, ground glass opacity (GGO) was found in the HRCT images, mainly distributed in the subpleural region of the lungs. The HRCT scans of six patients showed bilateral lobar lesions, mainly peripheral subpleural distribution; one patients showed unilateral lobar involvement. The right lung was more extensively involved than the left lung in six patients, and the lower lobe was more extensively involved than the upper lobe in five patients. The initial chest HRCT images of the lungs of COVID-19 patients had specific characteristics; the typical manifestations of the bilateral lungs showed extensive GGO-type infiltrate, with thickened vascular bundles and focal center consolidation. Pleural effusion, bilateral hilar, and mediastinal lymphadenopathy were rare.