著者
Young Joo KIM Narae LEE Jin YU Hanbin LEE Gayeon AN Sohyun BANG Jinhwa CHANG Dongwoo CHANG
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.17-0711, (Released:2018-12-05)
被引用文献数
8

The purpose of this study was to use magnetic resonance imaging (MRI) to compare the volumes and three-dimensional configurations of the soft palate and nasopharynx in non-brachycephalic and brachycephalic dogs with different body weights, and infer which factors influence nasopharyngeal volume. This was a retrospective observational study. The brain MRI medical records of all dogs referred to the Veterinary Medical Center, Chungbuk National University, between 2013 and 2016, for evaluation of intracranial disease were reviewed. There was a significant difference in the two-dimensional parameters including soft palate length/skull length ratio (P<0.01) and maximum soft palate thickness (P<0.01), and three-dimensional parameters which included soft palate volume (P<0.01), nasopharyngeal volume (P<0.01), soft palate/total upper airway volume ratio (P<0.01), and nasopharyngeal volume/total upper airway volume ratio (P<0.01), between brachycephalic and non-brachycephalic dog breeds. Nasopharyngeal volume correlated positively with the maximum soft palate thickness and body weight in all breeds. The three-dimensional morphologic grades of soft palate were significantly different between the two groups. In brachycephalic breeds, Grade 3 was observed in 33% of cases but was absent in non-brachycephalic breeds, where Grade 1 was present in 85% of the cases. We can conclude that three-dimensional morphology and upper airway volume are significantly different between brachycephalic and non-brachycephalic breeds, and body weight and maximum soft palate thickness are the key factors associated with a decreased nasopharyngeal volume.
著者
Hyeryoung JEONG Hanbin LEE Jaihyun JUNG Hyunryung KIM Jin YU Hyounglok YOON Youngjae LEE Jinhwa CHANG Dongwoo CHANG
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.18-0703, (Released:2021-01-19)

Unlike echocardiography, cardiac magnetic resonance imaging (cardiac MRI) results in a near-exact assessment of cardiac structures and function. However, most veterinary studies have focused on dogs with normal cardiac function. We hypothesized that there would be significant differences in cardiac measurements between cardiac MRI and echocardiography when left ventricular (LV) function was abnormal. This study was undertaken to compare measurements of LV function produced by cardiac MRI and echocardiography in dogs whose LV function was altered by pharmacological agents. This study was conducted with six healthy beagle dogs. We increased left ventricular contractility by administration of dobutamine; we decreased cardiac contractility with esmolol. Stroke volume measurements were made by using both cardiac MRI and echocardiography under seven different conditions with general anesthesia: control, three doses of esmolol (100, 200, and 500 µg/kg/min), and three doses of dobutamine (10, 20, and 50 µg/kg/min). Experiments involving each condition were conducted at least 1 week apart. When LV contractility was normal, ejection fraction (EF) and stroke volume (SV), as measured by echocardiography and cardiac MRI, were not significantly different. However, when contractility was changed by pharmacological agents, EF and SV were overestimated by echocardiography, compared to MRI. Evaluation of cardiac function in patients treated with pharmacological agents should be conducted carefully because EF and SV measured by echocardiography can be overestimated, compared with EF and SV obtained by cardiac MRI.
著者
Haengbok CHEON Wooshin CHOI Youngjae LEE Donghoon LEE Juhyung KIM Ji-Houn KANG Kijeong NA Jinhwa CHANG Dongwoo CHANG
出版者
公益社団法人 日本獣医学会
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
vol.74, no.11, pp.1461-1467, 2012 (Released:2012-12-01)
参考文献数
30
被引用文献数
5 19 1

The aim of this study was to assess age-related changes and anatomic variation in trabecular bone mineral density (tBMD) using quantitative computed tomography (QCT) in normal cats. Seventeen normal cats were included in this study and divided into the following 3 age groups:6 years (n=3). A computed tomographic scan of each vertebra from the 12th thoracic to the 7th lumbar spine and the pelvis was performed with a bone-density phantom (50, 100 and 150 mg/cm3, calcium hydroxyapatite, CIRS phantom®). On the central transverse section, the elliptical region of interest (ROI) was drawn to measure the mean Hounsfield unit (HU) value. Those values were converted to equivalent tBMD (mg/cm3) by use of the bone-density phantom and linear regression analysis (r2 >0.95). The mean tBMD value of the thoracic vertebrae (369.4 ± 31.8 mg/cm3) was significantly higher than that of the lumbar vertebrae (285 ± 58.1 mg/cm3). The maximum tBMD occurred at the T12, T13 and L1 levels in all age groups. There was a statistically significant difference in the mean tBMD value among the 3 age groups at the T12 (PPP=0.013), respectively. The present study suggests that age-related changes and anatomic variation in tBMD values should be considered when assessing tBMD using QCT in cats with bone disorders.
著者
Haengbok CHEON Wooshin CHOI Youngjae LEE Donghoon LEE Juhyung KIM Ji-Houn KANG Kijeong NA Jinhwa CHANG Dongwoo CHANG
出版者
公益社団法人 日本獣医学会
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.11-0579, (Released:2012-07-06)
被引用文献数
5 19

The aim of this study was to assess age-related changes and anatomic variation in trabecular bone mineral density (tBMD) using quantitative computed tomography (QCT) in normal cats. Seventeen normal cats were included in this study and divided into the following 3 age groups: <6 months (n=4); 2–5 years (n=10); and >6 years (n=3). A computed tomographic scan of each vertebra from the 12th thoracic to the 7th lumbar spine, and the pelvis was performed with a bone-density phantom (50, 100, and 150 mg/cm3, calcium hydroxyapatite, CIRS phantom®). On the central transverse section, the elliptical region of interest (ROI) was drawn to measure the mean Hounsfield unit (HU) value. Those values were converted to equivalent tBMD (mg/cm3) by use of the bone-density phantom and linear regression analysis (r2>0.95). The mean tBMD value of the thoracic vertebrae (369.4 ± 31.8 mg/cm3) was significantly higher than that of the lumbar vertebrae (285 ± 58.1 mg/cm3). The maximum tBMD occurred at the T12, T13, and L1 levels in all age groups. There was a statistically significant difference in the mean tBMD value among the 3 age groups at the T12 (P<0.001), T13 (P<0.001), and L4 levels (P=0.013), respectively. The present study suggests that age-related changes and anatomic variation in tBMD values should be considered when assessing tBMD using QCT in cats with bone disorders.