著者
Ilaria My Stefano Bordignon Mahi Butt Laura Rottner Lemoine Marc Fabian Moser Jan-Per Wenzel Julius Obergassel Ruben Schleberger Julia Moser Leon Dinshaw Paulus Kirchhof Bruno Reissmann Feifan Ouyang Kyoung-Ryul Julian Chun Boris Schmidt Andreas Rillig Andreas Metzner
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0220, (Released:2023-06-06)
参考文献数
10
被引用文献数
2

Background: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI).Methods and Results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68±11.3 years mean age, left atrial volume index 38.6±14.8 mL/m2) were included. 241/412 (58.5%) PVs were successfully isolated with a single shot (SS), with a time-to-isolation of 11.6±8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes’ impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5±6.6 vs. 18.6±6.5 Ohm). Concordantly, higher temperature rise was observed in the SS vs. non-SS applications (10.9±4.9℃ vs. 9.6±4.7℃).Conclusions: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.
著者
Tuomas Kiviniemi Marja Puurunen Axel Schlitt Andrea Rubboli Pasi Karjalainen Wail Nammas Paulus Kirchhof Fausto Biancari Gregory YH Lip KE Juhani Airaksinen
出版者
日本循環器学会
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-14-0792, (Released:2014-10-09)
参考文献数
31
被引用文献数
9 21

Background:We explored 12-month clinical outcomes of 929 patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI) with bare-metal stents (BMS) vs. drug-eluting stents (DES) from the prospective multicenter AFCAS (Atrial Fibrillation undergoing Coronary Artery Stenting) registry.Methods and Results:Endpoints included the first occurrence of major adverse cardiac and cerebrovascular events (MACCE), defined as a composite of all-cause death, myocardial infarction (MI), target vessel revascularization, definite/probable stent thrombosis (ST), transient ischemic attack or stroke. Bleeding events were defined according to the Bleeding Academic Research Consortium criteria. Altogether, 673 (72.4%) patients received BMS and 220 (23.7%) at least one DES. Patients treated with DES more often had diabetes and prior ischemic events, and a longer stent length (P<0.05 for all), whereas patients treated with BMS more often had heart failure and were more likely to present with acute ST-elevation MI (P<0.05 for both). At 12-month follow-up, rates and risks of MACCE and total bleeding events were comparable between the groups (22.0% with BMS vs. 19.5% with DES, P=0.51, hazard ratio (HR) 0.89, 95% confidence interval (CI) 0.63–1.25 for DES) and (19.5% vs. 15.0%, respectively, P=0.16, HR 0.75, 95% CI 0.51–1.09 for DES). Definite/probable ST was more frequent in the BMS group (1.9% vs. 0%, respectively, P=0.046).Conclusions:In real-world patients with AF undergoing PCI, DES use was associated with outcomes comparable to those with BMS without excess bleeding complications. More ST was seen in BMS-treated patients.