著者
Ilaria My Stefano Bordignon Mahi Butt Laura Rottner Lemoine Marc Fabian Moser Jan-Per Wenzel Julius Obergassel Ruben Schleberger Julia Moser Leon Dinshaw Paulus Kirchhof Bruno Reissmann Feifan Ouyang Kyoung-Ryul Julian Chun Boris Schmidt Andreas Rillig Andreas Metzner
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0220, (Released:2023-06-06)
参考文献数
10
被引用文献数
2

Background: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI).Methods and Results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68±11.3 years mean age, left atrial volume index 38.6±14.8 mL/m2) were included. 241/412 (58.5%) PVs were successfully isolated with a single shot (SS), with a time-to-isolation of 11.6±8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes’ impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5±6.6 vs. 18.6±6.5 Ohm). Concordantly, higher temperature rise was observed in the SS vs. non-SS applications (10.9±4.9℃ vs. 9.6±4.7℃).Conclusions: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.
著者
Christian-Hendrik Heeger Enida Rexha Sabrina Maack Laura Rottner Thomas Fink Shibu Mathew Tilman Maurer Christine Lemeš Andreas Rillig Peter Wohlmuth Bruno Reissmann Roland Richard Tilz Feifan Ouyang Karl-Heinz Kuck Andreas Metzner
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-19-1144, (Released:2020-04-18)
参考文献数
20
被引用文献数
17

Background:The second-generation cryoballoon (CB2) has demonstrated high procedural efficacy and convincing clinical success rates for pulmonary vein isolation (PVI). Nevertheless, data on the impact of different ablations protocols on durability are limited. The aim was to comparing the durability of PVI following 3 different ablation strategies in patients with recurrence of atrial fibrillation or atrial tachycardia undergoing repeat procedures.Methods and Results:In 192 patients, a total of 751 PVs were identified. All PVs were successfully isolated during index PVI. Thirty-one out of 192 (16%) patients were treated with a bonus-freeze protocol (group 1), 67/192 (35%) patients with a no bonus-freeze protocol (group 2), and 94/192 (49%) patients with a time-to-effect-guided protocol (group 3). Persistent PVI was documented in 419/751 (55.8%) PVs, and in 41/192 (21%) patients, all PVs were persistently isolated. The total rate of PV reconnection was not significantly different between the groups (P=0.134) and the comparison of individual PVs revealed no differences (P-values for RSPV: 0.424, RIPV: 0.541, LSPV: 0.788, LIPV: 0.346, LCPV: 0.865). The procedure times were significantly reduced by omitting the bonus-freeze and applying individualized application times (group 1: 123.4±31.5 min, group 2: 112.9±39.8 min, group 3: 86.67±28.4 min, P<0.001).Conclusions:Comparing 3 common ablation protocols, no differences for durable PVI were detected. Procedure times were significantly reduced by omitting the bonus-freeze cycle and by applying individualized application times.
著者
Christian-Hendrik Heeger Amr Abdin Shibu Mathew Bruno Reissmann Kivanc Yalin Spyridon Liosis Thomas Fink Riccardo Proietti Charlotte Eitel Julia Vogler Christine Lemeš Tilman Maurer Andreas Rillig Roza Meyer-Saraei Tobias Graf Peter Wohlmuth Britta Goldmann Feifan Ouyang Karl-Heinz Kuck Andreas Metzner Roland Richard Tilz
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-19-0151, (Released:2019-06-28)
参考文献数
22
被引用文献数
20

Background:Second-generation cryoballoon (CB2)-based pulmonary vein isolation (PVI) has demonstrated encouraging results in the treatment of atrial fibrillation (AF). This study sought to assess data on the safety, efficacy and clinical success of CB2-based PVI in patients with heart failure (HF) and reduced ejection fraction (HFrEF).Methods and Results:CB2-based PVI was performed in 551 consecutive patients in 3 highly experienced EP centers. Patients with HF and LVEF ≤40% were included (HFrEF group, n=50/551, 9.1%). Data were compared with propensity score-matched patients without HF and preserved left ventricular EF (LVEF) (n=50, control group). The median LVEF was HFrEF: 37% (35, 40) and control: 55% (55, 55), P<0.0001. Major periprocedural complications were registered in 4/50 (8%, HFrEF group) and 3/50 (6%, control group), P=0.695. The 12-month freedom from AF recurrence was 73.1% (95% confidence interval (CI): 61–88, HFrEF group) and 72.6% (95% CI: 61–87, control group), P=0.25. NYHA class decreased from 2.4±0.8 (baseline) to 1.7±0.8 at 12-month follow-up (P<0.0001). LVEF improved from a median of 37% (35, 40) prior to ablation to a median of 55% (40, 55), P<0.0001.Conclusions:CB2-based PVI in patients with HFrEF appeared to be safe, was associated with comparable periprocedural complications and showed promising clinical success rates equal to those for patients with preserved LVEF. NYHA class and LVEF significantly improved at 12-month follow-up.
著者
Christian-Hendrik Heeger Enida Rexha Sabrina Maack Laura Rottner Thomas Fink Shibu Mathew Tilman Maurer Christine Lemeš Andreas Rillig Peter Wohlmuth Bruno Reissmann Roland Richard Tilz Feifan Ouyang Karl-Heinz Kuck Andreas Metzner
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.84, no.6, pp.902-910, 2020-05-25 (Released:2020-05-25)
参考文献数
20
被引用文献数
8 17

Background:The second-generation cryoballoon (CB2) has demonstrated high procedural efficacy and convincing clinical success rates for pulmonary vein isolation (PVI). Nevertheless, data on the impact of different ablations protocols on durability are limited. The aim was to comparing the durability of PVI following 3 different ablation strategies in patients with recurrence of atrial fibrillation or atrial tachycardia undergoing repeat procedures.Methods and Results:In 192 patients, a total of 751 PVs were identified. All PVs were successfully isolated during index PVI. Thirty-one out of 192 (16%) patients were treated with a bonus-freeze protocol (group 1), 67/192 (35%) patients with a no bonus-freeze protocol (group 2), and 94/192 (49%) patients with a time-to-effect-guided protocol (group 3). Persistent PVI was documented in 419/751 (55.8%) PVs, and in 41/192 (21%) patients, all PVs were persistently isolated. The total rate of PV reconnection was not significantly different between the groups (P=0.134) and the comparison of individual PVs revealed no differences (P-values for RSPV: 0.424, RIPV: 0.541, LSPV: 0.788, LIPV: 0.346, LCPV: 0.865). The procedure times were significantly reduced by omitting the bonus-freeze and applying individualized application times (group 1: 123.4±31.5 min, group 2: 112.9±39.8 min, group 3: 86.67±28.4 min, P<0.001).Conclusions:Comparing 3 common ablation protocols, no differences for durable PVI were detected. Procedure times were significantly reduced by omitting the bonus-freeze cycle and by applying individualized application times.