Kenzo Hiraoka Yuji Sakai Hiroyuki Kubota Satoshi Ninomiya Stephanie Rankin-Turner
出版者
The Mass Spectrometry Society of Japan
雑誌
Mass Spectrometry (ISSN:2187137X)
巻号頁・発行日
vol.12, no.1, pp.A0114, 2023-01-31 (Released:2023-01-31)
参考文献数
35
被引用文献数
1

Among the various types of cluster secondary ion mass spectrometry (SIMS), electrospray droplet impact/secondary ion mass spectrometry (EDI/SIMS) is unique due to its high ionization efficiency and non-selective atomic/molecular-level surface etching ability. In this study, EDI/SIMS was applied to the non-selective etching of synthetic polymers of polystyrene (PS) and poly(9,9-di-n-octylfluonyl-2,7diyl) (PFO) deposited on a silicon substrate. The polymers gave characteristic fragment ions and the mass spectra remained unchanged with prolonged EDI irradiation time, indicating that non-selective etching can be achieved by EDI irradiation, a finding that is consistent with our previous reports based on EDI/X-ray photoelectron spectroscopy analyses. From the irradiation time and film thickness, the etching rates for PS and PFO were roughly estimated to be 0.6 nm/min and 0.15 nm/min, respectively, under the experimental conditions that were used. After the depletion of polymer sample on the surface, ion signals originating from the exposed silicon substrate were observed. This indicates that EDI/SIMS is applicable to the analysis of the interface of multilayered films composed of organic and inorganic materials.
著者
Kenzo Hiraoka Osamu Ariyada Dilshadbek T. Usmanov Lee C. Chen Satoshi Ninomiya Kentaro Yoshimura Sen Takeda Zhang Yu Mridul K. Mandal Hiroshi Wada Stephanie Rankin-Turner Hiroshi Nonami
出版者
The Mass Spectrometry Society of Japan
雑誌
Mass Spectrometry (ISSN:2187137X)
巻号頁・発行日
vol.9, no.1, pp.A0092, 2020-12-04 (Released:2020-12-04)
参考文献数
61
被引用文献数
17

In 2007, probe electrospray ionization/mass spectrometry (PESI/MS) was developed. In this technique, the needle is moved down along a vertical axis and the tip of the needle touched to the sample. After capturing the sample at the needle tip, the needle is then moved up and a high voltage is applied to the needle at the highest position to generate electrospray. Due to the discontinuous sampling followed by the generation of spontaneous electrospray, sequential and exhaustive electrospray takes place depending on the surface activity of the analytes. As modified versions of PESI, dipping PESI (dPESI), sheath-flow PESI (sfPESI) and adjustable sfPESI (ad-sfPESI) have been developed. These methods are complementary to each other and they can be applicable to surface and bulk analysis of various biological samples. In this article, the characteristics of these methods and their applications to real samples will be reviewed.