著者
Keigo Iwazaki Toshiya Kojima Takahide Murasawa Jun Yokota Hikaru Tanimoto Jun Matsuda Nobuaki Fukuma Takumi Matsubara Yu Shimizu Gaku Oguri Eriko Hasumi Hitoshi Kubo Kyungho Chang Katsuhito Fujiu Issei Komuro
出版者
International Heart Journal Association
雑誌
International Heart Journal (ISSN:13492365)
巻号頁・発行日
vol.59, no.3, pp.626-629, 2018-05-31 (Released:2018-05-30)
参考文献数
8

A cardiac resynchronization therapy defibrillator (CRT-D) (Medtronic Inc. Protecta XT) was implanted in a 67-year-old man who had cardiac sarcoidosis with extremely low cardiac function. He had ventricular tachycardia which was controlled by catheter ablation, medication and pacing. The programmed mode was DDI, lower rate was 90 beats/minute, paced AV delay was 150 ms, and the noncompetitive atrial pacing (NCAP) function was programmed as 300 ms.After his admission for pneumonia and heart failure, we changed his DDI mode to a DDD mode because he had atrial tachycardia, which led to inadequate bi-ventricular pacing. After a while, there were cycle lengths which were longer than his device setting and alternately varied. We were able to avoid this phenomenon with AV delay of 120 ms and NCAP of 200 ms.NCAP is an algorithm which creates a gap above a certain period after the detection of an atrial signal during the postventricular atrial refractory period of the pacemaker. This is to prevent atrial tachycardia and repetitive non-reentrant ventriculoatrial (VA) synchrony in the presence of retrograde VA conduction. But in this case, NCAP algorithm induced much lower rate than the programmed basic lower rate. This situation produced some arrhythmias and exacerbated symptoms of heart failure. This had to be paid attention to, especially when the device was programmed at high basic heart rate.
著者
Toshiya Kojima Katsuhito Fujiu Nobuaki Fukuma Hiroshi Matsunaga Tsukasa Oshima Jun Matsuda Takumi Matsubara Yu Shimizu Gaku Oguri Eriko Hasumi Hiroyuki Morita Issei Komuro
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-17-1114, (Released:2018-04-13)
参考文献数
20
被引用文献数
7

Background:Periprocedural anticoagulation is important in catheter ablation (CA) of atrial fibrillation (AF) and there is increasing evidence that uninterrupted vitamin K antagonist (VKA) therapy is superior to interrupted anticoagulation strategies. Since the emergence of direct oral anticoagulants (DOACs), numerous studies have shown promising results for their use in uninterrupted strategies. However, further studies are needed to further define the efficacy and safety of performing AF ablation with uninterrupted factor XA inhibitors or direct thrombin inhibitors.Methods and Results:We have performed CA of AF without discontinuation of either VKA or DOAC therapy since April 2014. A total of 376 patients with AF underwent CA including pulmonary vein isolation. All of the patients were divided into 2 groups (uninterrupted VKA or uninterrupted DOACs). Anticoagulation with DOACs was associated with fewer complications than uninterrupted VKA therapy (P=0.04). There were significant differences between groups in the rates of congestive heart failure, left ventricular ejection fraction, body weight, and estimated glomerular filtration rate and of the CHADS2, CHA2DS2-VASc and HAS-BLED scores. Therefore, we also analyzed the results using the propensity score-matching method. We found no significant difference in periprocedural complications between uninterrupted VKA or DOACs therapy (P=0.65).Conclusions:CA of AF without discontinuation of DOACs is not inferior to CA without discontinuation of a VKA, with regard to ischemic or hemorrhagic complications.