著者
町田 圭吾 近藤 武士 岩本 静男 倉渕 隆 遠藤 智行 飯野 由香利
出版者
公益社団法人 空気調和・衛生工学会
雑誌
空気調和・衛生工学会大会 学術講演論文集 平成18年 (ISSN:18803806)
巻号頁・発行日
pp.611-614, 2006-09-05 (Released:2017-08-31)

The experiment to grasp the indoor thermal environment when air supplied from air supply opening was carried out. The difference of the indoor thermal environment by height of air supply opening was compared. The air temperature distribution, the velocity of the wind distribution, CDP, and EHT were used as evaluation indexes. The fluctuation between upper and lower temperature in front of the air supply opening was decreased by raising the height of the installation.
著者
山岸 航 川瀬 貴晴 岩淵 弘太
出版者
公益社団法人 空気調和・衛生工学会
雑誌
空気調和・衛生工学会大会 学術講演論文集 平成18年 (ISSN:18803806)
巻号頁・発行日
pp.699-702, 2006-09-05 (Released:2017-08-31)

Latest power generation efficiency of photovoltaic systems is about 15%. We carried out 2 experiments to improve the power generation efficiency. One is on the improvement of the efficiency by using solar reflections from walls or eaves. Another is on the improvement of the efficiency by cooling a photovoltaic module by spraying water.
著者
飯野 由香利 岩本 静男 倉渕 隆 近藤 武士 遠藤 智行
出版者
公益社団法人 空気調和・衛生工学会
雑誌
空気調和・衛生工学会大会 学術講演論文集 平成18年 (ISSN:18803806)
巻号頁・発行日
pp.1185-1188, 2006-09-05 (Released:2017-08-31)

The experiment was conducted in order to clarify influences of outdoor air supplied through openings on thermal environment in rooms heated by floor heating systems. The ari supply openings of various heights and types were used in respective experiment cases. The following results were obtained: (1) Draught Rating (DR) was increased by sypplied outdoor air in any heights of air supply openings and openings with natural ventilation systems. The DR in areas near the air supply openings were higher than DR in far area. (2) Influences of outdoor air supplied through openings in the heights of more than 1600mm above floor were small on thermal environment. (3) The air supply openings with mechanical ventilaion systems made better thermal temperature than openings with natural ventilation systems because mechanical ventilaion systems controled temperatures of supply air.
著者
岡部 実 大澤 元毅 桑沢 保夫
出版者
公益社団法人 空気調和・衛生工学会
雑誌
空気調和・衛生工学会大会 学術講演論文集 平成18年 (ISSN:18803806)
巻号頁・発行日
pp.511-514, 2006-09-05 (Released:2017-08-31)

Floor heating system is widly used in Japan. Japanese building code about indoor air quality was based on 28 degree temperature and 50% humidity in summer. Floor heating system have made of plywood, MDF and other woodbased material included folmaldehyde and when running floor heating in winter, temperature inside the floor heating system become above 28 degree. When floor heating system running in winter, it is required to measure the indoor air quality in the full size house. Hot-water system and electric heater system was constructed for interior finish of the house and indoor chemical substance concentration was measured. Folmaldehyde concentration showed below the 100ug/m^3 for running floor heating system in winter.