- 著者
-
堀 雅寛
木村 守
小泉 孝行
- 出版者
- 一般社団法人 電気学会
- 雑誌
- 電気学会論文誌D(産業応用部門誌) (ISSN:09136339)
- 巻号頁・発行日
- vol.137, no.3, pp.230-237, 2017-03-01 (Released:2017-03-01)
- 参考文献数
- 16
This paper describes the inverter drive characteristics of a 2.4 MW permanent magnet generator (PMG) for a diesel electric propulsion system. We demonstrated the relations between the PWM (Pulse-Width Modulation) pulse patterns and temperature rise in a permanent magnet in a PMG. Additionally, we demonstrated that inverter failure has a significant impact on the current and torque in a PMG.