著者
堀 雅寛 木村 守 小泉 孝行
出版者
一般社団法人 電気学会
雑誌
電気学会論文誌D(産業応用部門誌) (ISSN:09136339)
巻号頁・発行日
vol.137, no.3, pp.230-237, 2017-03-01 (Released:2017-03-01)
参考文献数
16

This paper describes the inverter drive characteristics of a 2.4 MW permanent magnet generator (PMG) for a diesel electric propulsion system. We demonstrated the relations between the PWM (Pulse-Width Modulation) pulse patterns and temperature rise in a permanent magnet in a PMG. Additionally, we demonstrated that inverter failure has a significant impact on the current and torque in a PMG.