著者
横町 和志 西丸 英治 藤岡 知加子 木口 雅夫 石風呂 実 船間 芳憲 粟井 和夫
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.70, no.10, pp.1166-1172, 2014 (Released:2014-10-20)
参考文献数
13

Purpose: For emergency or pediatric head CT scans, a simplified pillow made of hard sponge instead of a dedicated head holder may be used if it is difficult to immobilize the head. However, the radiation dose when using a simplified head holder may be increased due to radiation absorption by the patient couch if the automatic exposure control (AEC) system is used. In this phantom study, we compared the radiation dose delivered when using a dedicated and a simplified head holder. Materials and Methods: We used a dedicated-type and a pillow-type head holder made of hard sponge (simplified head holder). We placed a 20 cm-diameter cylindrical phantom made of water-equivalent material and an anthropomorphic head phantom in the head holders and then scanned them five times with a 64-detector CT scanner (VCT, GE Healthcare). We performed step-and-shoot and helical scanning with AEC; the noise index was set to 2.8. We measured the radiation dose using fluorescent glass dosimeters in the head phantom and the image noise at five sites in the cylindrical phantom. All values were averaged. Results: With step-and-shoot scans, the mean image noise with the dedicated and the simplified head holder was 3.30 ± 0.05 [SD] and 3.20 ± 0.05, respectively. With helical scans they were 3.00 ± 0.09 and 2.88 ± 0.03, respectively. There was no statistically significant difference (p = 0.02 and 0.04, Student’s t-test). The radiation doses with the dedicated and the simplified head holder were 58.6 and 70.4 mGy, respectively, for step-and-shoot scanning and 41.8 and 49.0 mGy, respectively, for helical scanning. The doses were thus significantly higher with the simplified head holder for both step-and-shoot and helical scanning (p < 0.01 and < 0.01). Conclusion: We recommend the use of a dedicated head holder for head scanning with AEC since the radiation dose was lower than with the simplified head holder.
著者
藤淵 俊王 藤田 克也 五十嵐 隆元 西丸 英治 堀田 昇吾 桜井 礼子 小野 孝二
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.77, no.2, pp.160-171, 2021 (Released:2021-02-20)
参考文献数
21
被引用文献数
2

Purpose: To investigate the actual condition of the crystalline lens equivalent dose and effective dose according to the type of job and the type of duties in a medical institution. We also sought to clarify effective exposure reduction strategies. Methods: Equivalent crystalline lens doses, effective doses, job type, and duties for 8656 persons · year were obtained from 17 medical facilities. We analyzed the relationship between the effective dose and the crystalline lens equivalent dose in uniform exposure control and non-uniform exposure control conditions. Exposure data were obtained for 13 unique job types and duties. Results: The ratio of the lens equivalent dose to the effective dose of non-uniform exposure managers was 2 to 6 times and varied depending on the occupation. The percentage of persons whose annual lens equivalent dose exceeded 20 mSv was 4.75% for medical doctors, 1.17% for nurses, and 0.24% for radiological technologists. Highly exposed tasks included doctors in cardiology and gastroenterology performing angiography and endoscopy, nurses in endoscopy, and radiological technologists in radiography and CT examinations. Conclusion: Thorough unequal exposure control for operations with high crystalline lens exposure, radiation protection education, and effective use of proper personal protective equipment such as the use of radiation protection glasses may reduce lens exposure levels.