Purpose: For emergency or pediatric head CT scans, a simplified pillow made of hard sponge instead of a dedicated head holder may be used if it is difficult to immobilize the head. However, the radiation dose when using a simplified head holder may be increased due to radiation absorption by the patient couch if the automatic exposure control (AEC) system is used. In this phantom study, we compared the radiation dose delivered when using a dedicated and a simplified head holder. Materials and Methods: We used a dedicated-type and a pillow-type head holder made of hard sponge (simplified head holder). We placed a 20 cm-diameter cylindrical phantom made of water-equivalent material and an anthropomorphic head phantom in the head holders and then scanned them five times with a 64-detector CT scanner (VCT, GE Healthcare). We performed step-and-shoot and helical scanning with AEC; the noise index was set to 2.8. We measured the radiation dose using fluorescent glass dosimeters in the head phantom and the image noise at five sites in the cylindrical phantom. All values were averaged. Results: With step-and-shoot scans, the mean image noise with the dedicated and the simplified head holder was 3.30 ± 0.05 [SD] and 3.20 ± 0.05, respectively. With helical scans they were 3.00 ± 0.09 and 2.88 ± 0.03, respectively. There was no statistically significant difference (p = 0.02 and 0.04, Student’s t-test). The radiation doses with the dedicated and the simplified head holder were 58.6 and 70.4 mGy, respectively, for step-and-shoot scanning and 41.8 and 49.0 mGy, respectively, for helical scanning. The doses were thus significantly higher with the simplified head holder for both step-and-shoot and helical scanning (p < 0.01 and < 0.01). Conclusion: We recommend the use of a dedicated head holder for head scanning with AEC since the radiation dose was lower than with the simplified head holder.
著者
粟井 和夫 中野 由紀子 石田 万里
出版者
広島大学
雑誌
基盤研究(C)
巻号頁・発行日
2013-04-01

心臓CT受診患者45人を対象に、CT検査前、直後、24-48時間後の末梢血リンパ球を採取し、DNA二本鎖切断修復関連蛋白(γH2AX)の定量を行い、CTにおける被曝の物理的指標(CTDI, DLP, SSDE)とDNAの損傷の程度の相関を検討した。また体の体幹部を模倣したファントムの中心に血液を封入したシリンジを挿入し、それに対してCT撮影を行い、CTDI、DLP、SSDEとDNAの損傷が相関するか否か検討した。臨床検討およびファントムの検討により、DNA二重鎖はCT直後より切断され、その程度はCTの物理線量と相関することが判明した。
著者
高須 深雪 田中 信弘 坂井 晃 粟井 和夫
出版者
広島大学
雑誌
基盤研究(C)
巻号頁・発行日
2011

多発性骨髄腫と対照間で骨梁幅、骨異方性度、フラクタル次元に有意差を検出した。胃切除後症例と対照間、および肝動脈塞栓療法除後症例と対照間で続発性骨粗鬆症有病率、骨梁パラメータおよび有限要素解析による破壊荷重、スティフネスに有意差を検出した。横断的検討では多発性骨髄腫骨折群と非骨折群間で、骨梁パラメータおよび機械特性に有意差を検出した。平成23年度よりcalibration phantomを用い、CTによる体積骨密度および組織骨密度で評価している。上述の各検討において組織骨密度に有意差を検出している。