著者
村山 大知 坂井 上之 米山 正己 能勢 毅一 畠山 英久 渡邉 一寿 越智 茂博
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.77, no.6, pp.572-580, 2021 (Released:2021-06-20)
参考文献数
17

Magnetic resonance angiography (MRA) using ultra-short TE (uTE) is known to be used for the evaluation of cerebral aneurysm after treatment such as clipping and coiling. However, conventional uTE sequences are not appropriate as an additional imaging sequence for 3D time-of-flight (TOF)-MRA because it is not possible to shorten scan time and acquire selective-volume imaging. To solve the problem, we focused on the combination of uTE sampling and 3D radial scan sequences. In this study, we examined the optimal imaging parameters of the proposed uTE-MRA. A simulated blood flow phantom with stents (Enterprise) and titanium clips (YASARGIL) was used for optimizing the TR, flip angle (FA), and radial percentage. The signal intensity in the simulated vessel was measured in each imaging condition, and the ratio of the presence or absence of a stent was evaluated as a relative in-stent signal (RIS). In addition, the diameter of the signal loss of the simulated artery was measured for each imaging condition, and signal loss length (SLL) of a clip was calculated from the average value. The RIS improved with increasing the FA and shortening the TR, but it did not change by changing the radial percentage. The SLL became smaller at the coil as the FA increased, but there was no significant difference between the intersection and the blade. There was also no significant difference between TR and radial percentage. The effective imaging conditions for uTE-MRA to improve the vascular description of the evaluation after treatment of cerebral aneurysms with metallic devices were those with large FA and short TR.
著者
鈴木 伸忠 伊藤 肇 坂井 上之 越智 茂博 梁川 範幸
出版者
公益社団法人 日本放射線技術学会
雑誌
日本放射線技術学会雑誌 (ISSN:03694305)
巻号頁・発行日
vol.76, no.5, pp.474-482, 2020 (Released:2020-05-20)
参考文献数
20
被引用文献数
1

We report on the construction of a system for managing prior information and injection condition used for contrast enhance CT examination using radiology information system (RIS). Contrast dose administration system using the RIS was possible to retrospectively investigate optimal injection conditions from the database. As the prior information, we designed the patientʼs profile information of the hospital information system (HIS) to reflect the patientʼs height, weight, and kidney function (eGFR, Cre), which is necessary information for contrast enhance CT examination, in the RIS. By adding E-Box (DICOM Gateway) to the injector, it became possible to reflect the amount of contrast agent used in patients and injection conditions at contrast enhance CT examination. The contrast agent use information is transmitted to RIS by using modality performed procedure step (MPPS). Database of injection condition at contrast enhance CT examination using the RIS, to determine the optimal injection conditions retrospectively. By utilizing the massive amount of clinical information stored in the RIS, the amount of contrast agent and injection condition at contrast enhance CT examination could be optimized. Reproducibility of the contrast effect can be secured. In the CE, evidence system linked with RIS, when considering the reproducibility at follow-up observation and comparative diagnosis in clinical practice, the contrast effect could be made constant. Contrast dose administration system using the RIS was useful.