著者
吉田 和佳奈 齋藤 栄 酒向 孫市 野田 政充 川口 諭 新井 一也 安齋 沙織 久保田 聡 渋谷 清 町田 充 堀野 忠夫 青木 学一 尾鳥 勝也
出版者
公益社団法人 日本薬学会
雑誌
YAKUGAKU ZASSHI (ISSN:00316903)
巻号頁・発行日
vol.142, no.8, pp.893-900, 2022-08-01 (Released:2022-08-01)
参考文献数
12

“Leukerin® powder 10%” containing mercaptopurine (6-MP) is an oral anticancer drug that requires careful handling. As a powder formulation, there are risks of exposure due to scattering during dispensing and possible 6-MP contamination to other drugs due to adhesion to the packaging machine. We previously reported that wiping with an alcohol-containing towel is useful for removing scattered powder after dispensing. However, it is recommended to wipe disk-type powder-packaging machines with water instead of cleaning with the alcohol-containing towel. Hence, we scattered 6-MP powder 100 mg (total amount of 6-MP: 10 mg), and then wiped with water three times using different types of cloth each time. We confirmed that third time wiping cloth did not have any 6-MP. Furthermore, we confirmed that the adhering 6-MP could be removed by wipe-cleaning (water-wiping twice and dry-wiping once) after dispensing 6-MP powder at two pharmacies that routinely dispensed 6-MP powder using a disk-type powder-packaging machine. In addition, we confirmed the adhesion of 6-MP in parts of the machine not cleaned by wipe-cleaning and also in parts that were washed only with water, in both the pharmacies. Based on the above observations, we recommend the following steps for cleaning disk-type powder-packaging machines after dispensing 6-MP powder: (1) wipe-cleaning that includes water-wiping twice and then dry-wiping once, (2) cleaning all areas of the packaging machine, and (3) wipe-cleaning with water before washing with water.
著者
青木 学一 小田 さつき 久保田 聡 齋藤 栄 横田 訓男 柴﨑 淳 渋谷 清 酒向 孫市 尾鳥 勝也
出版者
公益社団法人 日本薬学会
雑誌
YAKUGAKU ZASSHI (ISSN:00316903)
巻号頁・発行日
vol.141, no.1, pp.125-133, 2021-01-01 (Released:2021-01-01)
参考文献数
15
被引用文献数
1

The immunosuppressant azathioprine (AZA) is classified as a hazardous drug. AZA contamination during tablet-splitting increases exposure risk. However, there is no study on contamination and exposure during AZA tablet splitting and dispensing. AZA tablet splitting and dispensing methods were classified based on whether tweezers are used during splitting and packaging. In Dispensing Method (1), no tweezers were used in either step. In Dispensing Method (2), no tweezers were used during tablet splitting, but were used during packaging. In Dispensing Method (3), tweezers were used in both steps. After AZA half-tablet split-dispensing, we quantified the adherent AZA removed from the tools, packaging machines, and dispensing counters by three consecutive wipings with water-dampened polypropylene cloths. A large amount of AZA adhered to the gloves used in Dispensing Methods (1) and (2), wherein tablets were placed with gloved hands, compared with Dispensing Method (3), wherein tablets were held with tweezers. Thus, the gloves must be replaced before touching the packaging paper during the final step. After three consecutive wipings, AZA was not detected at most of the sites in the third round. Thus, we recommend that (1) AZA tablet splitting should be performed while wearing gloves, (2) the gloves should be changed before packaging the half tablets, and (3) the tools, packaging machines, and dispensing counters should be wiped twice or thrice with a water-dampened cloth after dispensing.