著者
Ji Woong Roh SungA Bae Thomas W. Johnson Seok-Jae Heo Yongcheol Kim Deok-Kyu Cho Jung-Sun Kim Byeong-Keuk Kim Donghoon Choi Myeong-Ki Hong Yangsoo Jang Myung Ho Jeong on behalf of the KAMIR-NIH Investigators
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-23-0189, (Released:2023-05-30)
参考文献数
21
被引用文献数
3

Background: In the setting of acute myocardial infarction (AMI), there are no data regarding the benefits of intravascular ultrasound (IVUS) for chronic kidney disease (CKD) patients.Methods and Results: This study used data from the Korea Acute Myocardial Infarction Registry, a large, multicenter prospective cohort. We evaluated 1,759 patients with AMI and CKD, defined as estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2, and patients were classified into 2 groups: with and without IVUS. The primary outcome was target lesion failure (TLF) at 3 years. The hazard ratio (HR) of TLF according to eGFR was also analyzed. A total of 1,759 patients with AMI and CKD who underwent IVUS-guided PCI (19.2%) had a significantly lower risk of TLF at 3 years (8.9% vs. 15.3%; HR 0.55; 95% confidence interval [CI]: 0.38 to 0.81; P=0.002) than those who underwent angiography-guided PCI, regardless of their eGFR and the presence of end-stage renal disease (ESRD). The results were consistent after confounder adjustment and inversed probability weighting.Conclusions: In patients with CKD and AMI who underwent PCI with 2nd-generation DES implantation, the use of IVUS guidance was associated with a significant reduction in 3-year TLF and showed consistently favorable outcomes regardless of eGFR and ESRD.
著者
Jung-Sun Kim Hancheol Lee Yongsung Suh Hui-Nam Pak Geu-Ru Hong Chi Young Shim Cheol-Woong Yu Hyun-Jong Lee Woong-Chol Kang Eun-Seok Shin Rak-Kyeong Choi Saibal Kar Jai-Wun Park Do-Sun Lim Yangsoo Jang
出版者
日本循環器学会
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-15-1134, (Released:2016-03-17)
参考文献数
28
被引用文献数
2 25

Background:The aim of this study was to evaluate clinical outcome after left atrial appendage (LAA) occlusion in real clinical practice and compare between Amplatzer cardiac plug (ACP) and Watchman.Methods and Results:From October 2010 to February 2015, 96 successful LAA occlusion procedures were performed using either ACP (n=50) or Watchman device (n=46) in non-valvular atrial fibrillation (AF) patients (59 male; age, 65.1±9.4 years; CHADS2, 2.5±1.2; CHA2DS2-VASC, 3.9±1.6; HAS-BLED, 2.7±1.3). The procedure success rate was 96.8%. There were serious complications in 4 patients (4.1%; 2 cardiac tamponade, 1 device embolization, and 1 major bleed). The anticoagulation cessation rate after 6 weeks was 92.7%. During mean 21.9-month follow-up, the incidence of death, stroke, systemic embolization and major bleeding was 5.2%, 4.2%, 0% and 1.0%, respectively. On transesophageal echocardiography of 93 patients within 6 months after the procedure, 24 residual leaks were observed (25.8%; 2 mild, 18 moderate, and 4 major). Clinical outcome was similar for the 2 devices, but peridevice leakage was more frequent with the Watchman than the ACP.Conclusions:LAA occlusion was feasible in non-valvular AF patients with high risk of stroke and hemorrhage. The ACP and Watchman devices were similar in terms of procedural and clinical outcomes.