著者
Toshiki TAKAMIZAWA Eizo HIROKANE Keiichi SAI Ryo ISHII Ryota AOKI Wayne W. BARKMEIER Mark A. LATTA Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2022-130, (Released:2022-11-08)
参考文献数
42
被引用文献数
3

This study investigated the enamel and dentin bond durability of a two-step adhesive system, using a universal adhesive-derived primer (G2-Bond Universal [GU]), and compared it with the two conventional, two-step, self-etch adhesive systems (Clearfil SE Bond 2 [CS] and OptiBond XTR [OX]) under thermal cycling (TC) and long-term water storage (WS). The shear bond strengths to bovine enamel and dentin were determined using the etch-and-rinse and self-etch modes. Twelve specimens per test group were prepared and further divided into the following subgroups: 1) subjected to TC, 2) long-term WS, and 3) WS for 24 h (baseline). The enamel and dentin bond durability of GU was superior to those of CS and OX in different etching modes and under different degradation conditions. The latest two-step adhesive system, which utilizes universal adhesives’ benefits in its primer, might offer durable clinical bonding performances and can be widely used in a clinical setting.
著者
Kabun Yamauchi Akimasa Tsujimoto Carlos A. Jurado Yusuke Shimatani Yuko Nagura Toshiki Takamizawa Wayne W. Barkmeier Mark A. Latta Masashi Miyazaki
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.18-0433, (Released:2019-10-21)
参考文献数
31
被引用文献数
28

In this study, dentin bond fatigue resistance and interfacial science characteristics of universal adhesives through etch-and-rinse and self-etch modes were investigated. Resin composite was bonded to human dentin with four universal adhesives, namely, Adhese Universal, All-Bond Universal, G-Premio Bond, and Scotchbond Universal Adhesive. The initial bond strengths, bond fatigue strengths, and interfacial science characteristics of the universal adhesives with dentin through etch-and-rinse and self-etch modes were determined. Bond fatigue resistance (initial bond strength and bond fatigue strength) of universal adhesives in etch-and-rinse mode showed no significant difference in contrast to that in self-etch mode and was material-dependent regardless of the etching mode. Although phosphoric acid conditioning of dentin did not have a strong impact on the bond fatigue resistance, surface free energy and parameters of dentin were significantly decreased by etching and by application of universal adhesives regardless of etching mode. Changes in γS and γSh for when universal adhesive was applied to etched and ground dentin were significantly different depending on the adhesive. The results suggest that bonding performance of universal adhesives was effective in both etching modes; however, bonding mechanisms may be different for each.
著者
Akimasa Tsujimoto Wayne W. Barkmeier Toshiki Takamizawa Hidehiko Watanabe William W. Johnson Mark A. Latta Masashi Miyazaki
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.16-0815, (Released:2018-01-29)
参考文献数
40
被引用文献数
13

This study evaluated the simulated localized wear of resin luting cements for universal adhesive systems using different curing modes. Five resin luting cements for universal adhesive systems were evaluated and subsequently subjected to wear challenge in a Leinfelder-Suzuki wear simulation device. Overall, 20 specimens from each resin luting cement were photo-cured for 40 s (dual-cure group), and 20 specimens of each material were not photo-cured (chemical-cure group). Simulated localized wear was generated using a stainless steel ball-bearing antagonist in water slurry of polymethylmethacrylate beads. In addition, scanning electron microscopy (SEM) observations of resin luting cements and wear facets were conducted. Significant differences in simulated wear and SEM observations of wear facets were evident among the materials in the dual- and chemical-cure groups. The simulated wear and SEM observations of wear facets of G-CEM LinkForce and Panavia V5 were not influenced by the curing mode. SEM observations of resin luting cements were material dependent. In most cases, dual curing appears to ensure greater wear resistance of resin luting cements than chemical curing alone. The wear resistance of some resin luting cements appears to be material dependent and is not influenced by the curing mode.
著者
Shunichi SUDA Akimasa TSUJIMOTO Wayne W. BARKMEIER Kie NOJIRI Yuko NAGURA Toshiki TAKAMIZAWA Mark A. LATTA Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2017-059, (Released:2017-11-23)
参考文献数
51
被引用文献数
20

The effect of phosphoric acid pre-etching on enamel bond fatigue durability of universal adhesives and two-step self-etch adhesives was investigated. Four universal adhesives and three two-step self-etch adhesives were used. The initial shear bond strengths and shear fatigue strengths to enamel with and without phosphoric acid pre-etching using the adhesives were determined. SEM observations were also conducted. Phosphoric acid pre-etching of enamel was found to increase the bond fatigue durability of universal adhesives, but its effect on two-step self-etch adhesives was material-dependent. In addition, some universal adhesives with phosphoric acid preetching showed similar bond fatigue durability to the two-step self-etch adhesives, although the bond fatigue durability of universal adhesives in self-etch mode was lower than that of the two-step self-etch adhesives. Phosphoric acid pre-etching enhances enamel bond fatigue durability of universal adhesives, but the effect of phosphoric acid pre-etching on the bond fatigue durability of two-step self-etch adhesives was material-dependent.
著者
Kazutaka HIRAI Akimasa TSUJIMOTO Kie NOJIRI Hirofumi UETA Toshiki TAKAMIZAWA Wayne W. BARKMEIER Mark A. LATTA Masashi MIYAZAKI
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2016-019, (Released:2017-06-23)
参考文献数
31
被引用文献数
4

The influence of photoirradiation conditions on dentin bond durability and interfacial characteristics of universal adhesives was investigated. Universal adhesives were applied to the dentin surfaces and photoirradiated with 100 mW/cm2 for 40 s, 200 mW/cm2 for 20 s, and 400 mW/cm2 for 10 s. A resin composite was bonded to dentin to determine shear bond strength after 24 h water storage and 30,000 thermal cycles, and water contact angle of cured adhesive were measured by the sessile drop method. Greater dentin bond strengths after 24 h water storage and 30,000 thermal cycles were achieved under these conditions at light intensity exceeding 200 mW/cm2. Universal adhesives photoirradiated above 200 mW/cm2 exhibited significantly higher water contact angles than those at 100 mW/cm2. The results of this study suggested that the photoirradiation conditions affect the dentin bond durability and interfacial characteristics of universal adhesives even at the same total energy.
著者
Akimasa TSUJIMOTO Wayne W. BARKMEIER Toshiki TAKAMIZAWA Mark A. LATTA Masashi MIYAZAKI
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2016-131, (Released:2017-02-01)
参考文献数
32
被引用文献数
49

The purpose of this study was to investigate the depth of cure, flexural properties and volumetric shrinkage of low and high viscosity bulk-fill giomers and resin composites. Depth of cure and flexural properties were determined according to ISO 4049, and volumetric shrinkage was measured using a dilatometer. The depths of cure of giomers were significantly lower than those of resin composites, regardless of photo polymerization times. No difference in flexural strength and modulus was found among either high or low viscosity bulk fill materials. Volumetric shrinkage of low and high viscosity bulk-fill resin composites was significantly less than low and high viscosity giomers. Depth of cure of both low and high viscosity bulk-fill materials is time dependent. Flexural strength and modulus of high viscosity or low viscosity bulk-fill giomer or resin composite materials are not different for their respective category. Resin composites exhibited less polymerization shrinkage than giomers.
著者
Akimasa TSUJIMOTO Wayne W. BARKMEIER Toshiki TAKAMIZAWA Mark A. LATTA Masashi MIYAZAKI
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
vol.35, no.3, pp.418-424, 2016-05-31 (Released:2016-06-01)
参考文献数
37
被引用文献数
1 46

The mechanical properties, volumetric shrinkage and depth of cure of a short fiber-reinforced resin composite (SFRC) were investigated in this study and compared to both a bulk fill resin composite (BFRC) and conventional glass/ceramic-filled resin composite (CGRC). Fracture toughness, flexural properties, volumetric shrinkage and depth of cure of the SFRC, BFRC and CGRC were measured. SFRC had significantly higher fracture toughness than BFRCs and CGRCs. The flexural properties of SFRC were comparable with BFRCs and CGRCs. SFRC showed significantly lower volumetric shrinkage than the other tested resin composites. The depth of cure of the SFRC was similar to BFRCs and higher than CGRCs. The data from this laboratory investigation suggests that SFRC exhibits improvements in fracture toughness, volumetric shrinkage and depth of cure when compared with CGRC, but depth of cure of SFRC was similar to BFRC.
著者
Fumi YOSHIDA Akimasa TSUJIMOTO Ryo ISHII Kie NOJIRI Toshiki TAKAMIZAWA Masashi MIYAZAKI Mark A. LATTA
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
vol.34, no.6, pp.855-862, 2015-11-27 (Released:2015-12-01)
参考文献数
28
被引用文献数
2 37

This study investigates the influence of surface treatment of contaminated lithium disilicate and leucite glass ceramic restorations on the bonding efficacy of universal adhesives. Lithium disilicate and leucite glass ceramics were contaminated with saliva, and then cleaned using distilled water (SC), or 37% phosphoric acid (TE), or hydrofluoric acid (CE). Specimens without contamination served as controls. The surface free energy was determined by measuring the contact angles formed when the three test liquids were placed on the specimens. Bond strengths of the universal adhesives were also measured. Saliva contamination and surface treatment of ceramic surfaces significantly influenced the surface free energy. The bond strengths of universal adhesives were also affected by surface treatment and the choice of adhesive materials. Our data suggest that saliva contamination of lithum disilicate and leucite glass ceramics significantly impaired the bonding of the universal adhesives, and reduced the surface free energy of the ceramics.