著者
Kana HAYASHI Hiroyasu KUROKAWA Makoto SAEGUSA Ryota AOKI Toshiki TAKAMIZAWA Atsushi KAMIMOTO Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2023-007, (Released:2023-07-15)
参考文献数
29

This study aimed to determine the influence of surface roughness of the color adjustment potential restoration of universal resin composites. A structural colored resin composite (Omnichroma, OC) and a pigment-employed universal shade resin composite (Beautifil Unishade, BU) were used. Each resin composite was placed in a cavity to determine its ability to match the color of artificial teeth. The surface of the resin composites was polished with #800- or #2000-grit SiC paper before performing color measurements. One-way analysis of variance and Tukey post hoc tests were performed (α=0.05). The color difference (ΔE*ab) ranged from 2.5–3.9 for OC and 1.8–8.7 for BU. OC has a more stable color adjustment than BU. The color adjustment potential of universal resin composites was affected by the surface roughness of the restorations.
著者
Takeshi NAKAMURA Makoto HAYASHI Muneaki TAMURA Masahiro KAKETANI Tomoka ITO Toshiki TAKAMIZAWA Yusuke SUZUKI Takuya YASUKAWA Akiyoshi SUGAWARA Osamu TAKEICHI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2022-250, (Released:2023-03-18)
参考文献数
32

The recently developed biphasic calcium phosphate cement (BCPC) consists of α-tricalcium phosphate-tetracalcium phosphate as the solid phase and calcium phosphate solution as the liquid phase. BCPC powder is composed of a single solid solution with a monomodal size distribution. Here, we used a bacterial leakage model to examine the utility of BCPC as a seal for root-end filling. We prepared large (median particle size=9.96 µm; BCPC-L) and small (median particle size=4.84 µm; BCPC-S) BCPC powders. In total, 45 single-rooted teeth were instrumented, resected at the root-end, and retrofilled with experimental materials. Mineral trioxide aggregate (MTA) was used as the control. After visual confirmation of BCPC powder size and retrofilling quality by microscopy, bacterial leakage tests were conducted using Enterococcus faecalis. The bacterial leakage tests did not reveal any significant differences between BCPC-S and MTA. Our findings suggest that BCPC-S is useful for root-end filling.
著者
Toshiki TAKAMIZAWA Eizo HIROKANE Keiichi SAI Ryo ISHII Ryota AOKI Wayne W. BARKMEIER Mark A. LATTA Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2022-130, (Released:2022-11-08)
参考文献数
42
被引用文献数
3

This study investigated the enamel and dentin bond durability of a two-step adhesive system, using a universal adhesive-derived primer (G2-Bond Universal [GU]), and compared it with the two conventional, two-step, self-etch adhesive systems (Clearfil SE Bond 2 [CS] and OptiBond XTR [OX]) under thermal cycling (TC) and long-term water storage (WS). The shear bond strengths to bovine enamel and dentin were determined using the etch-and-rinse and self-etch modes. Twelve specimens per test group were prepared and further divided into the following subgroups: 1) subjected to TC, 2) long-term WS, and 3) WS for 24 h (baseline). The enamel and dentin bond durability of GU was superior to those of CS and OX in different etching modes and under different degradation conditions. The latest two-step adhesive system, which utilizes universal adhesives’ benefits in its primer, might offer durable clinical bonding performances and can be widely used in a clinical setting.
著者
Mone SHOJI Hiroyasu KUROKAWA Nao TAKAHASHI Runa SUGIMURA Toshiki TAKAMIZAWA Kei IWASE Shun KATSUKI Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-318, (Released:2022-03-24)
参考文献数
42
被引用文献数
5

The purpose of this study was to investigate the protective effect of a glass ionomer cement (GIC) consisting of fluoro-zinc-silicate glass on the demineralization of bovine dentin using the ultrasonic pulse-echo method. The findings were compared with those obtained using a conventional GIC. Slabs of dentin from bovine teeth were sliced, shaped into a rectangular form, and immersed in 0.5 M ethylenediaminetetraacetic acid solution at 25ºC for 6 days, followed by storage in distilled water for 3 days. After demineralization, they were immersed in artificial saliva with and without the GIC specimens. The propagation times of the longitudinal ultrasonic waves in the samples were measured. The ultrasonic velocities of the fluoro-zinc-silicate glass-containing GICs were significantly increased 2–3 days after the start of the experiment and showed an upward trend thereafter. These findings indicate that the GICs containing fluoro-zinc-silicate glass might exhibit the potential to promote remineralization in the dentin.
著者
Nao TAKAHASHI Hiroyasu KUROKAWA Kengo WAKAMATSU Eizo HIROKANE Toshiki TAKAMIZAWA Masashi MIYAZAKI Nobuya KITAHARA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-154, (Released:2021-09-23)
参考文献数
27
被引用文献数
7

This study investigated the bonding performance of two different types of resin cements to computer-aided design/computer-aided manufacturing (CAD/CAM) composite blocks based on the shear bond strength (SBS) test. A silane-containing self-adhesive resin cement (Panavia SA Cement Universal) and resin luting cement (Block HC Cem) with a primer, were used. Specimens were fabricated from three different types of CAD/CAM composite blocks, and their surfaces were blasted with alumina. Resin cements were bonded to the specimens, and their SBSs were measured after 15 min, 24 h, and after being subjected to thermal cycling for 10,000 and 30,000 cycles. Three-way ANOVA for bond strength revealed that CAD/CAM composite block, resin cement and storage time significantly influenced the SBS values, and the three-way interactions between the evaluated factors, and all the interactions were significant. It was concluded that the bonding performance of resin cements to CAD/CAM composite blocks were material and storage period dependent.
著者
Tatsuya IIJIMA Hiroyasu KUROKAWA Toshiki TAKAMIZAWA Eizo HIROKANE Nao TAKAHASHI Kengo WAKAMATSU Shunichi SUDA Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2021-011, (Released:2021-06-30)
参考文献数
40

The purpose of this study was to investigate the ability of polishing paste containing surface pre-reacted glass-ionomer (S-PRG) filler to prevent acidic attack on tooth enamel surfaces. Resin composites were filled in the standardized cavities and finished with silicon carbide paper. These specimens were divided into three groups: the unpolished “control” group, the “PRG” group polished with S-PRG paste, and the “DDP” group polished with diamond-containing polishing paste. Following polishing, the specimens were immersed in a lactic acid buffer solution for 28 days. Optical coherence tomography (OCT) signals were measured to obtain the signal intensity and width at 1/e2 at selected locations on the enamel surface adjacent to the restoration. Although signal intensity significantly increased in all groups, widths at 1/e2 did not change significantly in the PRG group. For both the control and DDP groups, signal intensity and width at 1/e2 increased and decreased over time, respectively.
著者
Hajime OOUCHI Toshiki TAKAMIZAWA Tomohiko TAMURA Ryo ISHII Akimasa TSUJIMOTO Masashi MIYAZAKI Nobuya KITAHARA
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2020-381, (Released:2021-04-20)
参考文献数
28
被引用文献数
6

This study investigates the flexural properties, Knoop hardness number (KHN), and wear behavior of computer-aided design and computer-aided manufacturing (CAD/CAM) resin blocks and compares these values with those of conventional resin composites for direct restoration (RCDs). Four CAD/CAM resin blocks and two RCDs are compared. Ten specimens per material are used to obtain the flexural properties according to ISO 6872 specifications, and five specimens per material are used for KHN measurement. For sliding impact wear testing, twelve specimens are prepared. Confocal laser scanning microscopy (LSM) is used to determine maximum facet depth and volume loss. Polished material surfaces and worn surfaces after wear testing are observed using scanning electron microscopy and LSM. While measured flexural properties and KHN are found to be material-dependent, CAD/CAM resin blocks exhibit higher wear resistance than RCDs. CAD/CAM resin blocks polymerized at high-pressure and high-temperature are found to exhibit wear behaviors far superior to those of RCDs.
著者
Yoshiyuki Amari Toshiki Takamizawa Ryo Kawamoto Yasuhiro Namura Ryosuke Murayama Munenori Yokoyama Akimasa Tsujimoto Masashi Miyazaki
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.20-0420, (Released:2020-12-30)
参考文献数
33
被引用文献数
4

Purpose: This study investigated the influence of professional mechanical tooth cleaning (PMTC) pastes on the surface texture of different subject materials.Methods: Two one-step PMTC pastes, Clinpro Cleaning Paste for PMTC (CP) and PRG Pro-Care Gel (PG), and multiple-step PMTC pastes, Merssage Regular (MR), Merssagge Fine (MF), and Merssage Plus (MP), were used. For comparison, PMTC was performed using distilled water without paste (DW). The subjected materials used were bovine enamel (ENA) and dentin (DEN), a resin composite (FSU), and lithium disilicate (IEC). The prepared specimens were polished using a #2000-grit silicon carbide paper. PMTC was performed using a brush at 1,000 rpm for 15 s.Results: The surface roughness (Ra) values of the specimens before and after PMTC were measured by laser scanning microscopy. The Knoop hardness number (KHN) of the subjected material was obtained. The types of PMTC pastes and subject materials had a significant influence on the Ra values and KHN. For the majority of subject materials, the descending order of Ra values after PMTC was MR > MF > CP > PG > MP > DW. The descending order of KHN of the materials was IEC > ENA > FSU > DEN.Conclusion: Although one-step PMTC pastes appeared to be effective, it is important to consider the subject material during PMTC.
著者
Nao TAKAHASHI Chiaki YABUKI Hiroyasu KUROKAWA Toshiki TAKAMIZAWA Yuta KASAHARA Makoto SAEGUSA Miho SUZUKI Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2019-247, (Released:2020-05-19)
参考文献数
28
被引用文献数
5

The aim of this study was to determine the influence of different surface treatments of CAD/CAM composite blocks on bonding effectiveness of resin cements, based on the shear bond strength test and the surface science examination. Specimens were fabricated from two types of CAD/CAM composite blocks (Cerasmart and VITA Enamic), and the specimen surfaces were alumina sandblasted. Specimen surfaces were treated with i) silane, ii) primer, and iii) silane+primer, then two types of cements (Block HC Cem and Super Bond) were bonded. After 24 h storage, bond strengths were measured. Surface free energy measurements were performed of the treated CAD/CAM composite blocks surfaces. The groups ii) and iii) showed significantly higher bond strengths than the group i), apart from VITA Enamic with Block HC Cem. Although the total surface free energy showed different trends in different surface treatments, a similar trend was found in both CAD/CAM composite blocks.
著者
Toshie HIDARI Toshiki TAKAMIZAWA Arisa IMAI Eizo HIROKANE Ryo ISHII Akimasa TSUJIMOTO Takayuki SUZUKI Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2019-154, (Released:2020-02-29)
参考文献数
37
被引用文献数
16

This study aimed to determine the role of the 10-methacryloyloxydecyl dihydrogen phosphate (MDP) in dentin bond durability of universal adhesive in etch-&-rinse mode through bond strength tests after different degradation conditions. This study used the MDP-containing universal adhesive, Clearfil Universal Bond Quick (CU), and an experimental adhesive (NM) made with the same ingredients as CU, excluding MDP. Shear bond strength (SBS) to dentin were obtained in etch-&-rinse mode with or without MDP. CU in self-etch mode was used as a comparison. The groups were divided into three types: 1) subjected to thermal cycling; 2) subjected to long-term water storage; and 3) stored in water for 24 h, as a baseline. The discrepancies in the mean SBS of the CU and NM groups become prominent with prolonged degradation periods. This study indicates that the MDP in universal adhesive might play a key role in enhancing dentin bond quality even when etch-&-rinse mode is used.
著者
Yasuhiro Namura Toshiki Takamizawa Yasuki Uchida Mizuki Inaba Daichi Noma Tomoko Takemoto Masashi Miyazaki Mitsuru Motoyoshi
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.62, no.1, pp.48-51, 2020 (Released:2020-01-29)
参考文献数
20
被引用文献数
8

Although there have been improvements in bracket systems precoated with adhesive, removal of adhesive remnants continues to be problematic. This study compared the hardness and maintainability of precoated adhesive with other commercial adhesives. Knoop hardness values were measured after light- or chemical-induced initial curing, immersion in distilled water at 37°C for 24 h and 1,000 and 10,000 thermal cycles after 24 h. Additionally, the forces required to move brackets by 0.5 mm were measured during bracket positioning, and brackets bonded to bovine enamel were examined by field-emission scanning electron microscopy. The Knoop hardness values of the precoated adhesives were lower than those of commercial resin composite adhesives, and hardness was dependent on the amount of filler in the resin matrix. The ability to maintain the device position may depend on the resin matrix composition. Precoated adhesives with less filler and more matrix material are light curable, and remnant resin may be easily removed.
著者
Kabun Yamauchi Akimasa Tsujimoto Carlos A. Jurado Yusuke Shimatani Yuko Nagura Toshiki Takamizawa Wayne W. Barkmeier Mark A. Latta Masashi Miyazaki
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.18-0433, (Released:2019-10-21)
参考文献数
31
被引用文献数
28

In this study, dentin bond fatigue resistance and interfacial science characteristics of universal adhesives through etch-and-rinse and self-etch modes were investigated. Resin composite was bonded to human dentin with four universal adhesives, namely, Adhese Universal, All-Bond Universal, G-Premio Bond, and Scotchbond Universal Adhesive. The initial bond strengths, bond fatigue strengths, and interfacial science characteristics of the universal adhesives with dentin through etch-and-rinse and self-etch modes were determined. Bond fatigue resistance (initial bond strength and bond fatigue strength) of universal adhesives in etch-and-rinse mode showed no significant difference in contrast to that in self-etch mode and was material-dependent regardless of the etching mode. Although phosphoric acid conditioning of dentin did not have a strong impact on the bond fatigue resistance, surface free energy and parameters of dentin were significantly decreased by etching and by application of universal adhesives regardless of etching mode. Changes in γS and γSh for when universal adhesive was applied to etched and ground dentin were significantly different depending on the adhesive. The results suggest that bonding performance of universal adhesives was effective in both etching modes; however, bonding mechanisms may be different for each.
著者
Shunsuke AKIBA Toshiki TAKAMIZAWA Akimasa TSUJIMOTO Nobuyuki MORITAKE Ryo ISHII Wayne W BARKMEIER Mark A LATTA Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2018-300, (Released:2019-06-21)
参考文献数
40
被引用文献数
12

We investigated the influence of different curing modes on the mechanical properties and wear behavior of dual-cure provisional resin-based composites (DCPRs). Three DCPRs and a self-curing bis-acryl provisional resin-based composite were used. Flexural strength (σF), elastic modulus (E), resilience (R), and fracture toughness (KIC) were measured. The specimens were fabricated with and without light irradiation, stored in distilled water at 37°C for 24 h, and subjected to 5,000 or 10,000 thermal cycles. For sliding impact wear testing, 12 specimens were prepared with and without light irradiation. The maximum facet depth and volume loss were determined using a noncontact profilometer. Some of the mechanical properties and wear behavior of DCPRs are affected by light irradiation. This study indicated that proper light irradiation is important in polymerization process of the DCPRs to enhance the wear resistance and some mechanical properties.
著者
Toshiki Takamizawa Akimasa Tsujimoto Ryo Ishii Maho Ujiie Mami Kawazu Toshie Hidari Takayuki Suzuki Masashi Miyazaki
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
vol.61, no.2, pp.276-283, 2019 (Released:2019-06-18)
参考文献数
33
被引用文献数
4

The purpose of this study was to examine the effect of desensitizing dentifrices containing stannous fluoride (SnF2) on dentinal tubule occlusion. Two experimental dentifrices with the same ingredients but different SnF2 concentrations (Group II, 0.4% w/w; Group III, 0.454% w/w) were used; distilled water was used in the control group (Group I). Third molars were collected from Japanese and American dental patients. The crowns were removed and sectioned to obtain dentin discs, which were further cut into quarters. Thirty-six specimens each from Japanese and American patients were divided into three sets (n = 12 each) and assigned to each of the three treatment groups. The specimens were brushed for 10 s twice per day for 4 days. After treatment, the discs were observed by scanning electron microscopy, and the extent of dentinal tubule occlusion in the images was expressed on a five-point categorical scale. Group II and III specimens from Japanese and American patients showed greater dentinal tube occlusion than those from Group I, but the differences were not statistically significant. The present results suggest that both SnF2 concentrations mitigate dentin hypersensitivity, regardless of patient ethnicity.
著者
Akimasa Tsujimoto Wayne W. Barkmeier Toshiki Takamizawa Hidehiko Watanabe William W. Johnson Mark A. Latta Masashi Miyazaki
出版者
Nihon University School of Dentistry
雑誌
Journal of Oral Science (ISSN:13434934)
巻号頁・発行日
pp.16-0815, (Released:2018-01-29)
参考文献数
40
被引用文献数
13

This study evaluated the simulated localized wear of resin luting cements for universal adhesive systems using different curing modes. Five resin luting cements for universal adhesive systems were evaluated and subsequently subjected to wear challenge in a Leinfelder-Suzuki wear simulation device. Overall, 20 specimens from each resin luting cement were photo-cured for 40 s (dual-cure group), and 20 specimens of each material were not photo-cured (chemical-cure group). Simulated localized wear was generated using a stainless steel ball-bearing antagonist in water slurry of polymethylmethacrylate beads. In addition, scanning electron microscopy (SEM) observations of resin luting cements and wear facets were conducted. Significant differences in simulated wear and SEM observations of wear facets were evident among the materials in the dual- and chemical-cure groups. The simulated wear and SEM observations of wear facets of G-CEM LinkForce and Panavia V5 were not influenced by the curing mode. SEM observations of resin luting cements were material dependent. In most cases, dual curing appears to ensure greater wear resistance of resin luting cements than chemical curing alone. The wear resistance of some resin luting cements appears to be material dependent and is not influenced by the curing mode.
著者
Shunichi SUDA Akimasa TSUJIMOTO Wayne W. BARKMEIER Kie NOJIRI Yuko NAGURA Toshiki TAKAMIZAWA Mark A. LATTA Masashi MIYAZAKI
出版者
The Japanese Society for Dental Materials and Devices
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2017-059, (Released:2017-11-23)
参考文献数
51
被引用文献数
20

The effect of phosphoric acid pre-etching on enamel bond fatigue durability of universal adhesives and two-step self-etch adhesives was investigated. Four universal adhesives and three two-step self-etch adhesives were used. The initial shear bond strengths and shear fatigue strengths to enamel with and without phosphoric acid pre-etching using the adhesives were determined. SEM observations were also conducted. Phosphoric acid pre-etching of enamel was found to increase the bond fatigue durability of universal adhesives, but its effect on two-step self-etch adhesives was material-dependent. In addition, some universal adhesives with phosphoric acid preetching showed similar bond fatigue durability to the two-step self-etch adhesives, although the bond fatigue durability of universal adhesives in self-etch mode was lower than that of the two-step self-etch adhesives. Phosphoric acid pre-etching enhances enamel bond fatigue durability of universal adhesives, but the effect of phosphoric acid pre-etching on the bond fatigue durability of two-step self-etch adhesives was material-dependent.
著者
Yukie TAMURA Toshiki TAKAMIZAWA Yutaka SHIMAMURA Shunsuke AKIBA Chiaki YABUKI Arisa IMAI Akimasa TSUJIMOTO Hiroyasu KUROKAWA Masashi MIYAZAKI
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2016-185, (Released:2017-07-12)
参考文献数
30
被引用文献数
12

The influences of air-powder polishing with glycine or sodium bicarbonate powders on shear bond strengths (SBS) and surface-free energies of universal adhesives were examined. Scotchbond Universal Adhesive (SU, 3M ESPE), G-Premio Bond (GP, GC), Adhese Universal (AU, Ivoclar Vivadent), and All-Bond Universal (AB, Bisco) were used in this study. Bovine dentin surfaces were air polished with glycine or sodium bicarbonate powders prior to the bonding procedure, and resin pastes were bonded to the dentin surface using universal adhesives. SBSs were determined after 24-h storage in distilled water at 37°C. Surface-free energy was then determined by measuring contact angles using three test liquids on dentin surfaces. Significantly lower SBSs were observed for dentin that was air-powder polished and surface-free energies were concomitantly lowered. This study indicated that air-powder polishing influences SBSs and surface-free energies. However, glycine powder produced smaller changes in these surface parameters than sodium bicarbonate.
著者
Kazutaka HIRAI Akimasa TSUJIMOTO Kie NOJIRI Hirofumi UETA Toshiki TAKAMIZAWA Wayne W. BARKMEIER Mark A. LATTA Masashi MIYAZAKI
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2016-019, (Released:2017-06-23)
参考文献数
31
被引用文献数
4

The influence of photoirradiation conditions on dentin bond durability and interfacial characteristics of universal adhesives was investigated. Universal adhesives were applied to the dentin surfaces and photoirradiated with 100 mW/cm2 for 40 s, 200 mW/cm2 for 20 s, and 400 mW/cm2 for 10 s. A resin composite was bonded to dentin to determine shear bond strength after 24 h water storage and 30,000 thermal cycles, and water contact angle of cured adhesive were measured by the sessile drop method. Greater dentin bond strengths after 24 h water storage and 30,000 thermal cycles were achieved under these conditions at light intensity exceeding 200 mW/cm2. Universal adhesives photoirradiated above 200 mW/cm2 exhibited significantly higher water contact angles than those at 100 mW/cm2. The results of this study suggested that the photoirradiation conditions affect the dentin bond durability and interfacial characteristics of universal adhesives even at the same total energy.
著者
Akimasa TSUJIMOTO Wayne W. BARKMEIER Toshiki TAKAMIZAWA Mark A. LATTA Masashi MIYAZAKI
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2016-131, (Released:2017-02-01)
参考文献数
32
被引用文献数
49

The purpose of this study was to investigate the depth of cure, flexural properties and volumetric shrinkage of low and high viscosity bulk-fill giomers and resin composites. Depth of cure and flexural properties were determined according to ISO 4049, and volumetric shrinkage was measured using a dilatometer. The depths of cure of giomers were significantly lower than those of resin composites, regardless of photo polymerization times. No difference in flexural strength and modulus was found among either high or low viscosity bulk fill materials. Volumetric shrinkage of low and high viscosity bulk-fill resin composites was significantly less than low and high viscosity giomers. Depth of cure of both low and high viscosity bulk-fill materials is time dependent. Flexural strength and modulus of high viscosity or low viscosity bulk-fill giomer or resin composite materials are not different for their respective category. Resin composites exhibited less polymerization shrinkage than giomers.
著者
Chie KANAZAWA Ryosuke MURAYAMA Tetsuya FURUICHI Arisa IMAI Shunichi SUDA Hiroyasu KUROKAWA Toshiki TAKAMIZAWA Masashi MIYAZAKI
出版者
日本歯科理工学会
雑誌
Dental Materials Journal (ISSN:02874547)
巻号頁・発行日
pp.2016-175, (Released:2016-12-06)
参考文献数
28

This study used an ultrasonic measurement device to monitor the setting behavior of silicone elastomeric impression materials, and the influence of temperature on setting behavior was determined. The ultrasonic device consisted of a pulser-receiver, transducers, and an oscilloscope. The two-way transit time through the mixing material was divided by two to account for the down-and-back travel path; then it was multiplied by the sonic velocity. Analysis of variance and the Tukey honest significant difference test were used. In the early stages of the setting process, most of the ultrasonic energy was absorbed by the elastomers and the second echoes were relatively weak. As the elastomers hardened, the sonic velocities increased until they plateaued. The changes in sonic velocities varied among the elastomers tested, and were affected by temperature conditions. The ultrasonic method used in this study has considerable potential for determining the setting processes of elastomeric impression materials.