著者
Kazutaka Aonuma Hiro Yamasaki Masato Nakamura Takashi Matsumoto Morimasa Takayama Kenji Ando Kenzo Hirao Masahiko Goya Yoshihiro Morino Kentaro Hayashida Kengo Kusano Yutaka Gomi Michael L. Main Takahiro Uchida Shigeru Saito
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
pp.CJ-20-0196, (Released:2020-06-26)
参考文献数
16
被引用文献数
15

Background:The SALUTE trial was a prospective, multicenter, single-arm trial to confirm the safety and efficacy of the WATCHMAN left atrial appendage closure (LAAC) device for stroke prevention in patients with nonvalvular atrial fibrillation (NVAF) in Japan.Methods and Results:A total of 54 subjects (including 12 roll-in subjects) with a WATCHMAN implant procedure were followed in 10 investigational centers. Follow-up visits were performed up to 2 years post-implant. The baseline CHA2DS2-VASc score was 3.6±1.6 and the baseline HAS-BLED score was 3.0±1.1. All 42 subjects in the intention to treat (ITT) cohort underwent successful implantation of the LAAC device without any serious complications, achieving the prespecified performance goal. The effective LAAC rate was maintained at 100% from 45 days to 12 months post-implant, achieving the prespecified performance goal. During follow-up, 1 subject died of heart failure, and 3 had ischemic strokes, but there were no cases of hemorrhagic stroke or systemic embolism. All events were adjudicated as unrelated to the WATCHMAN device/procedure by the independent Clinical Events Committee. All 3 ischemic strokes were classified as nondisabling based on no change in the modified Rankin scale score.Conclusions:Final results of the SALUTE trial demonstrated that the WATCHMAN LAAC device is an effective and safe alternative nonpharmacological therapy for stroke risk reduction in Japanese NVAF patients who are not optimal candidates for lifelong anticoagulation. (Trial Registration: clinicaltrials.gov Identifier NCT 03033134)
著者
Kazutaka Aonuma Hiro Yamasaki Masato Nakamura Tatsushi Ootomo Morimasa Takayama Kenji Ando Kenzo Hirao Yoshihiro Morino Kentaro Hayashida Kengo Kusano Michael L. Main Shigeru Saito
出版者
The Japanese Circulation Society
雑誌
Circulation Journal (ISSN:13469843)
巻号頁・発行日
vol.82, no.12, pp.2946-2953, 2018-11-24 (Released:2018-11-24)
参考文献数
22
被引用文献数
34

Background: The PROTECT AF and PREVAIL trials demonstrated that the WATCHMAN left atrial appendage (LAA) closure device is a reasonable alternative to warfarin therapy for stroke prevention in patients with nonvalvular atrial fibrillation (NVAF) in the USA and Europe. We conducted the SALUTE trial to confirm the safety and efficacy of the LAA closure therapy for patients with NVAF in Japan. Methods and Results: A total of 54 subjects (including 12 Roll-in) with NVAF who had a CHA2DS2-VASc score ≥2 were enrolled. All subjects were successfully implanted with the LAA closure device. No serious adverse events related to the primary procedure-safety endpoint occurred. The 2nd co-primary endpoint was a composite of all stroke, systemic embolism and cardiovascular/unexplained death. One ischemic stroke (1/42) occurred during the 6-month follow-up. The effective LAA closure rate defined as the 3rd co-primary endpoint was 100% (42/42) at both 45-day and 6-month follow-up. Conclusions: The procedural safety and 6-month results from the SALUTE trial demonstrated that the LAA closure device was safe and effective, similar to the results of large-scale randomized clinical trials, and provides a novel perspective of LAA closure for Japanese patients with NVAF in need of an alternative to long-term oral-anticoagulation. (Trial Registration: clinicaltrials.gov Identifier NCT 03033134)