著者
Seijirow GOYA Tomoki WADA Kazumi SHIMADA Daiki HIRAO Ryuji FUKUSHIMA Norio YAMAGISHI Miki SHIMIZU Ryou TANAKA
出版者
JAPANESE SOCIETY OF VETERINARY SCIENCE
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
vol.79, no.2, pp.380-386, 2017 (Released:2017-02-28)
参考文献数
42
被引用文献数
2 2

The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recumbency, left lateral-recumbency, supine position and prone position. After examinations in one posture, the same examination was demonstrated in another posture and repeated in all postures. In each posture, several standard TEE views were demonstrated: longitudinal cranial-esophageal aorta long-axis-view, transverse middle-esophageal mitral valve long-axis-view and transgastric middle short-axis-view. Additionally, echocardiographic parameters were attempted to measure, and direct blood pressure monitoring was performed in each view. As a result, oriented views, except for transgastric middle short-axis-view, could be obtained in all postures. Stroke volume and peak early diastolic velocity of mitral inflow were lower in supine position compared with those in right and left lateral-recumbency. Heart rate (HR) and systemic vascular resistance were higher in supine position compared with those in right and left lateral-recumbency. Left ventricular pre-ejection period/left ventricular ejection time corrected and uncorrected by HR were higher in supine position compared with those in right and left lateral-recumbency. In conclusion, longitudinal cranial-esophageal aorta long-axis-view and transverse middle-esophageal mitral valve long-axis-view provide useful information of interest anesthesia monitoring, because of their views enable to certainly obtain TEE parameters in various postures. Furthermore, TEE parameters allow to detect the changes of preload, afterload and HR that occur in supine position dogs.
著者
Kanako SAKAEDA Miki SHIMIZU
出版者
公益社団法人 日本獣医学会
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.15-0512, (Released:2016-01-30)
被引用文献数
4

Assessment of muscle mass is important for evaluating muscle function and rehabilitation outcomes. Ultrasound has recently been successfully used to estimate muscle mass in humans by measuring muscle thickness. This study attempted to standardize procedures for measuring femoral muscle thickness ultrasonographically, as well as quantify the reliability and validity of ultrasound evaluations of muscle thickness compared to measurements made by magnetic resonance imaging (MRI) in dogs. We evaluated the quadriceps femoris (QF), biceps femoris (BF), semitendinosus (ST) and semimembranosus (SM) muscles of 10 clinically healthy Beagle dogs. Scans were taken in 5 different sections divided equally between the greater trochanter and proximal patella. MRI was performed, followed by T1-weighted and contrast-enhanced T1-weighted imaging. Muscle cross-sectional area (CSA) was measured with MRI, and muscle thickness was measured with MRI and ultrasonography. The thickness of the QF, BF and ST muscles as measured by ultrasound at slices 1–3 (from the proximal end to the middle of the femur), 2–4 (middle of the femur) and 2 (more proximal than the middle of the femur), respectively, was correlated with muscle thickness and CSA as measured by MRI. These sites showed a flat interface between muscle and transducer and were situated over belly muscle. No correlation between measurement types was seen in SM muscle. We must confirm this assessment method for various breeds, sizes, ages and muscle pathologies in dogs, thereby confirming that muscle thickness as measured ultrasonographically can reflect muscle function.
著者
Seijirow GOYA Tomoki WADA Kazumi SHIMADA Daiki HIRAO Ryuji FUKUSHIMA Norio YAMAGISHI Miki SHIMIZU Ryou TANAKA
出版者
公益社団法人 日本獣医学会
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.16-0323, (Released:2016-12-16)
被引用文献数
2

The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recumbency, left lateral-recumbency, supine position and prone position. After examinations in one posture, the same examination was demonstrated in another posture and repeated in all postures. In each posture, several standard TEE views were demonstrated: longitudinal cranial-esophageal aorta long-axis-view, transverse middle-esophageal mitral valve long-axis-view and transgastric middle short-axis-view. Additionally, echocardiographic parameters were attempted to measure, and direct blood pressure monitoring was performed in each view. As a result, oriented views, except for transgastric middle short-axis-view, could be obtained in all postures. Stroke volume and peak early diastolic velocity of mitral inflow were lower in supine position compared with those in right and left lateral-recumbency. Heart rate (HR) and systemic vascular resistance were higher in supine position compared with those in right and left lateral-recumbency. Left ventricular pre-ejection period/left ventricular ejection time corrected and uncorrected by HR were higher in supine position compared with those in right and left lateral-recumbency. In conclusion, longitudinal cranial-esophageal aorta long-axis-view and transverse middle-esophageal mitral valve long-axis-view provide useful information of interest anesthesia monitoring, because of their views enable to certainly obtain TEE parameters in various postures. Furthermore, TEE parameters allow to detect the changes of preload, afterload and HR that occur in supine position dogs.
著者
Shun HIRASAWA Miki SHIMIZU Yuumi MARUI Miori KISHIMOTO Seiichi OKUNO
出版者
公益社団法人 日本獣医学会
雑誌
Journal of Veterinary Medical Science (ISSN:09167250)
巻号頁・発行日
pp.14-0089, (Released:2014-09-05)

We designed a new method of measuring the length of the ulnar nerve and determining standard values for F-wave parameters of the ulnar nerve in clinically normal beagles. Nerve length must be precisely measured to determine F-wave latency and conduction velocity. The length of the forelimb has served as the length of the ulnar nerve for F-wave assessments, but report indicates that F-wave latency is proportional to the length of the pathway traveled by nerve impulses. Therefore, we measured the surface distance from a stimulus point to the spinous process of the first thoracic vertebra (nerve length 1) and the anterior horn of the scapula (nerve length 2) as landmarks through the olecranon and the shoulder blade acromion. The correlation coefficients between the shortest F-wave latency and the length of nerves 1, 2 or the forelimb were 0.61, 0.7 and 0.58. Nerve length 2 generated the highest value. Furthermore, the anterior horn of the scapula was easily palpated in any dog regardless of well-fed body. We concluded that nerve length 2 was optimal for measuring the length of the ulnar nerve.